IMPORTANT Switch on only for Lipumax-P
-DA high-pressure pump. For the Lipumax-P
-DM, the pump is not switched "On/
Off" until during the disposal process,
Chap. 4.3.4 "Equipment level 2/
Lipumax-P -DM".
Switch on the "Off/On" switch of the
Î
high-pressure pump.
If the grease separator still contains a water trap from the installation or leak test, the
following „Filling" step can be omitted.
Fill the grease separator with freshwater up to the static water level (pipe invert, outlet
Î
socket):
All types: via the maintenance opening (raising system)
■
Alternative for type -DM: via the ball valve of the filling device
■
Alternative for Type -DA: Initiate automatic fresh water feed,
■
Chap. 4.2.1 „Control". Fresh water flows for the „Filling duration",
„Set values for commissioning" into the grease separator or the water level rises
automatically up to approx. 2/3 tank capacity.
Close maintenance opening.
Î
Open the penstock (if installed) in the inlet and outlet pipe.
Î
For version with disposal and cleaning equipment: Perform trial run,
Î
Chap. 4.3 „„Emptying and cleaning".
Grease separators Lipumax-P -B, -D, -DM, -DA
Operation
Chap. 4.2.3