Grease separators Lipumax-P -B, -D, -DM, -DA
Operation
Item Element
10
6
9
5
8
18
Explanation of the display elements
Item Element
3
11
12
13
14
23
22
21
120/ 144
Symbol
Function
Switch on manual
operation
Switch off
operation
Switch off
manual operation
Switch on
automatic mode
Switch on
automatic mode
Emergency stop
Symbol
Meaning
various
"Inner cleaning"
fault
(HP pump) HP
pump
"Inner cleaning"
mode
(HP pump)
Group alarm
"Filling"
mode
(filling device
solenoid valve)
First fill
Start program
item
Cleaning
program item
Explanation
The button is used to switch on the "Filling" (first
fill" of the housing (solenoid valve of the filling
device is opened).
Automatic switching off of manual mode takes
place after the preset filling time in minutes
(housing is approx. ²
/
³ full).
The button is used to switch off "inner cleaning"
(HP pump) mode (manual or automatic mode).
The button is used to switch off the (manual or
automatic) housing "Filling" mode (solenoid valve
of the filling device is closed).
The button is used to switch on the automatic
"inner cleaning" mode (HP pump) and controls it
via the "disposal program".
The button is used to switch on automatic
"Filling" mode of the housing. Solenoid valve is
opened or closed via the "disposal program".
Emergency stop
Explanation
Top line: Menu items or fault message text
Bottom line: Values or fault message text
LED lights up: Fault exists at HP pump.
Fault messages, e.g.:
If current consumption too high
Wrong rotating field
Malfunction: Pump not in operation
(switched off due to pressure drop longer
than 15 seconds in the suction pipe)
LED flashes: Manual operation is active
LED lights up: Automatic mode is active
LED lights up: At least one fault exists
LED flashes: Manual operation is active
LED lights up: Automatic mode is active
LED lights up: The necessary "first fill" is added
to the housing.
LED lights up: Automatic disposal program,
"Start" program item is active
LED flashes: Automatic disposal program,
"Cleaning" program item is active