Using the encoder NAVIGATION, the user can select Sens or Rs option for both
channels.
The parameter name between the <> symbols indicates the parameter value the
user can change using the VARIATION encoder, the parameter name between the
[ ] symbols indicates the parameter value the user can change using the ENTER
button.
In order to reset all automatic notch filters, select the Rs option of the desired
channel and push ENTER. The LC display will show the following:
Push the ENTER button in order to confirm, QUIT button in order to cancel.
Then the LCD display shows the previous information.
When the detection engine is active and the notch "variable" is set, the system
automatically removes the inserted notch filters gradually if the feedback
conditions are not present anymore.
Of course the system automatically puts new notch filters when new feedback
frequencies arise.
The LC display shows the disabled notch filters using the – character, and the
enabled notch filters using the i icon.
Pushing on QUIT button, the user freezes all automatic notch filters and stops the
detection engine.
23