tion of the code with an acoustic signal (sequence of
tones).
Replace the cover of the battery compartment. The valve
operating mechanism acknowledges correct reception of
the normal radio signal with an acoustic signal.
e) Setting the number of valve operating mechanisms
("An A")
Use this menu item to set the number of radiators (valve
operating mechanisms) to be controlled, e.g. if the heating
control is to control several valve operating mechanisms in
a large room.
If an additional valve operating mechanism is installed it
is very important that this valve operating mechanisms is
assigned the same safety code than the already installed
valve operating mechanisms.
Proceed as follows:
• Press the "PROG" key until "Sond" is displayed.
• Use the selection wheel to select the special function "An
A".
• To confirm your selection, briefly press the "PROG" key.
• The following data are displayed:
• Use the selection wheel to set the number of radiators
(1 to 8) and confirm your setting by briefly pressing the
"PROG" key.