21. Correction or calibration

If you have professional measuring equipment, you can correct possible deviations of the sensor.
The correction or calibration can be performed for the weather station and for the outdoor sensors (1-8). The
display of the outdoor sensors cannot be calibrated. If you have calibrated the values for the outdoor sensors in
the display of the weather station, the display of the outdoor sensor will show a different value.
Do not use any temperature or humidity values from radio, TV, newspaper, etc., since they do not correspond to
the precise value for your position. Use only professional measuring equipment for comparison.
The measuring range for the barometric pressure is at 10% to 99%. Settings above or below this are not possible.
Do not calibrate right after commissioning. Wait for a few hours, until the outdoor sensors and weather station
have adjusted to their ambience conditions and the measured values have stabilised.
Change the values with the buttons "+" or "-". Keep the respective button pressed for quick adjustment.
Push the button "ALARM": the set value is displayed without correction.
Push the "SET" button to save the set value and switch to the next setting.
If you do not push any button for approx. 30 seconds, the settings made until then are saved and setting mode is
left.

a) Temperature

The weather station must be in normal mode.
• Push and hold the buttons "SET" and "CHANNEL/+" for approx. 5 seconds. CORRECT is displayed.
• The display for the indoor temperature flashes. Use the buttons "+" or "-" to correct the value. The correction is made
in steps of 0.1 °C. Use the button "ALARM" to delete the correction again.
• Push the button "SET".
• The display for the outdoor temperature for sensor 1 flashes. Use the buttons "+" or "-" to correct the value. The correc-
tion is made in steps of 0.1 °C. Use the button "ALARM" to delete the correction again.
• Push the button "SET".
If several outdoor sensors are used, you can now perform temperature calibration for the next channel.
If no further outdoor sensors are used, the weather station will return to normal mode.

b) Humidity

The weather station must be in normal mode.
• Push and hold the buttons "SET" and "HISTORY/-" for approx. 5 seconds. CORRECT is displayed.
• The display for the indoor humidity flashes. Use the buttons "+" or "-" to correct the value. The correction is made in
steps of 1%. Use the button "ALARM" to delete the correction again.
• Push the button "SET".
• The display for the outdoor humidity for sensor 1 flashes. Use the buttons "+" or "-" to correct the value. The correction
is made in steps of 1%. Use the button "ALARM" to delete the correction again.
• Push the button "SET".
If several outdoor sensors are used, you can now perform humidity calibration for the next channel.
If no further outdoor sensors are used, the weather station will return to normal mode.