11 Device Information

Device information for air-to-water heat pumps (heating only)
1
Type and order code
2
Design
2.1
Degree of protection according to EN 60 529 for compact devices
and heating components
2.2
Installation location
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
Air
3.2
Temperature spread of heating water
(flow/return flow)
3.3
Heat output / COP
3.4
Sound power level device / outdoors
3.5
Sound pressure level at a distance of 1 m (indoors)
3.6
Heating water flow
with an internal pressure differential of
3.7
Air flow rate
with an external static pressure differential of
3.8
Refrigerant; total filling weight
3.9
Lubricant; total filling weight
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Air duct inlet and outlet (min. internal dimensions)
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
5.4
Nominal current A2 W35 / cosϕ
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against icing
7.3
Performance levels
7.4
Controller internal/external
1. See operating limits diagram
2. This data indicates the size and capacity of the system according to EN255 and EN14511. For an analysis of the economic and energy efficiency of the system, other parame-
ters,such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A7 / W35, have the fol-
lowingmeaning: External temperature 7°C and heating water flow temperature 35 °C.
3. Operation with 1 compressors
4. Operation with 2 compressors
5. The specified sound pressure level represents the free field level. The measured value can be up to 16 dB(A) higher, depending on the installation location. This value corresponds
to the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
6. See CE declaration of conformity
7. The heat circulating pump and the heat pump controller must always be ready for operation.
1
°C / °C
°C
at A7 / W35
K
2
at A-7 / W35
kW / ---
2
at A-7 / W45
kW / ---
2
at A2 / W35
kW / ---
2
at A7 / W35
kW / ---
2
at A7 / W45
kW / ---
2
at A10 / W35
kW / ---
dB(A)
5
dB(A)
m³/h / Pa
m³/h / Pa
m³/h / Pa
type / kg
type / litres
H x W x L cm
Inch
L x W cm
kg
V / A
2
A2 W35
kW
A
A / ---
7
WPL 150IR
WPL 190IR
IP21
Indoors
Indoors
Up to 58 / above 18
Up to 58 / above 18
-25 to +35
-25 to +35
9.8
5.0
9.7
3
7.1 / 2.8
6.7 / 2.6
8.9 / 2.6
4
12.7 / 2.8
11.7 / 2.6
16.1 / 2.7
3
6.2 / 2.3
4
11.1 / 2.2
3
9.3 / 3.2
8.6 / 3.1
10.9 / 3.0
4
14.9 / 3.1
14.6 / 3.0
19.2 / 3.2
3
10.7 / 3.7
10.4 / 3.5
13.1 / 3.4
4
17.1 / 3.5
17.0 / 3.4
24.8 / 3.6
3
10.1 / 3.0
4
16.6 / 2.9
3
12.8 / 4.0
12.6 / 3.8
14.1 / 3.5
4
20.0 / 3.8
19.5 / 3.7
26.6 / 3.8
58 / 64
62 / 68
54
1.8 /
3.3 /
2.3 /
6500
22000
5900
6600 / 0
9000 / 0
5500 / 25
8000 / 25
R404A / 3.7
R404A / 4.2
Polyolester / 3.0
Polyolester / 3.8
157 x 75 x 85
171 x 75 x 100
G 1 1/4'' external
G 1 1/4'' external
65 x 65
72.5 x 72.5
255
400 / 20 T
400 / 25 T
4.80
4.89
6.05
23
8.7 / 0.8
8.8 / 0.8
10.9 / 0.8
6
Automatic
Automatic
Reverse cycle
Reverse cycle
Yes (heated)
Yes (heated)
Yes
2
External
External
11
WPL 220IR
IP21
IP21
Indoors
Up to 58 / above 18
-25 to +35
5.0
9.9
5.0
8.8 / 2.5
9.9 / 2.4
9.2 / 2.3
15.5 / 2.4
19.1 / 2.7
16.1 / 2.3
8.4 / 2.2
8.7 / 2.0
14.4 / 2.1
15.0 / 1.9
10.5 / 3.0
12.8 / 3.0
12.6 / 3.0
18.7 / 3.1
22.3 / 3.0
22.2 / 3.0
12.6 / 3.3
14.2 / 3.1
13.9 / 3.1
24.2 / 3.4
25.8 / 3.4
25.1 / 3.3
12.1 / 2.9
12.8 / 2.9
23.7 / 2.9
24.6 / 2.8
13.8 / 3.4
14.7 / 3.1
14.3 / 3.2
25.4 / 3.6
29.1 / 3.6
28.7 / 3.5
62 / 68
58
58
4.5 /
2.3 /
4.6 /
22700
5900
23000
9000 / 0
8000 / 25
R404A / 4.0
Polyolester / 3.8
171 x 75 x 100
G 1 1/4'' external
72.5 x 72.5
310
314
400 / 25 T
6.11
7.40
7.44
24
25
11.0 / 0.8
13.4 / 0.8
13.4 / 0.8
6
6
Automatic
Reverse cycle
Yes (heated)
Yes
Yes
2
2
External
E-9