11 Device Information

Device information for air-to-water heat pumps (heating only)
1
Type and order code
2
Design
2.1
Model
2.2
Degree of protection according to EN 60 529
2.3
Installation location
3
Performance data
3.1
Operating temperature limits:
Heating water flow/return flow
Cooling, flow
Air (heating)
Air (cooling)
3.2
Temperature spread
of heating water
3.3
Heat output / COP
3.4
Temperature spread
of cooling water
3.5
Cooling capacity / COP
3.6
Sound power level device / outdoors
3.7
Sound pressure level at a distance of 1 m (indoors)
3.8
Heating water flow
with an internal pressure differential of
3.9
Free pressure, circulating pump (heating, max. stage)
3.10 Cooling water flow
with an internal pressure differential of
3.11 Free pressure, circulating pump (cooling, max. stage)
3.12 Air flow rate
with an external static pressure differential of
3.13 Refrigerant; total filling weight
3.14 Output of electric heating element (heat generator 2)
3.15 Lubricant; total filling quantity
4
Dimensions, connections and weight
4.1
Device dimensions
4.2
Device connections to heating system
4.3
Air duct inlet and outlet (min. internal dimensions)
4.4
Weight of the transportable unit(s) incl. packing
5
Electrical Connection
5.1
Nominal voltage; fuse protection
5.2
Nominal power consumption
5.3
Starting current with soft starter
5.4
Nominal current A2 W35 / cosϕ
6
Complies with the European safety regulations
7
Additional model features
7.1
Defrosting
Type of defrosting
Defrosting tray included
7.2
Heating water in device protected against freezing
7.3
Performance levels
7.4
Controller internal/external
1. See operating limits diagram
2. This data indicates the size and capacity of the system according to EN 255 and EN 14511. For an analysis of the economic and energy efficiency of the system, other parame-
ters,such as, in particular, the defrosting capacity, the bivalence point and regulation, should also be taken into consideration. The specified values, e.g. A7 / W35, have the fol-
lowingmeaning: External temperature 7 °C and heating water flow temperature 35 °C.
3. The specified sound pressure level represents the free field level. The measured value can be up to 16 dB(A) higher, depending on the installation location. This value corres-
pondsto the operating noise of the heat pump in heating operation with a flow temperature of 35 °C.
4. See CE declaration of conformity
5. The heat circulating pump and the heat pump controller must always be ready for operation.
1
°C / °C
°C
°C
°C
at A7 / W35
2
at A-7 / W35
kW / ---
2
at A-7 / W45
kW / ---
2
at A2 / W35
kW / ---
2
at A2 / W50
kW / ---
2
at A7 / W35
kW / ---
2
at A7 / W45
kW / ---
2
at A10 / W35
kW / ---
at A35 / W7
at A27 / W7
kW / ---
at A27 / W18
kW / ---
at A35 / W7
kW / ---
at A35 / W18
kW / ---
dB(A)
3
dB(A)
m³/h / Pa
Pa
m³/h / Pa
Pa
m³/h / Pa
type / kg
kW
type / litre
H x W x L cm
Inch
L x W cm
kg
V / A
2
A2 W35
kW
A
A / ---
5
WPL 60IMRRE
Reversible
IP21
Indoors
Up to 58 / above 18
+7 to +20
-25 to +35
+15 to +40
8.0
5.8 / 2.7
7.5 / 3.3
7.0 / 2.5
9.3 / 3.9
9.8 / 4.1
7.5
7.9 / 2.7
9.6 / 3.2
7.0 / 2.0
8.5 / 2.4
53 / 60
48
0.8 / 2700
1.6 / 11900
45000
2500 / 20
R404A / 3.3
2.0
Polyolester (POE) / 1.5
190 x 75 x 65
G 1'' external
44 x 44
250
230 / 20
2.27
30
12.3 / 0.8
4
Automatic
Reverse cycle
Yes (heated)
Yes
1
Internal
11
5.4 / 2.1
7.4 / 3.2
9.2 / 3.8
8.8 / 3.2
9.7 / 2.4
5.0
7.9 / 2.6
9.6 / 3.2
6.9 / 2.0
8.5 / 2.4
27000
2.33
12.7 / 0.8
E-9