Ventilation & Efficiency
Ventilation
EcoSmart™ Fires do not require any form of permanent fixture or fitting,
such as a flue for ventilation, a permanent connection or any kind of
fixed utility for fuel supply.
Bioethanol is safe to burn indoors without venting, because its main
by-products are carbon dioxide, water steam and heat.
Do not cover any existing ventilation systems or structures that are
built or installed within the chosen installation area.
To ensure adequate ventilation, make sure to follow the guidelines in
the table below.
Underwriters Laboratories calculates adequate air exchange as follows:
In a house of typical construction, that is, one that is not of unusually
tight construction due to heavy insulation and tight seals against air
infiltration, an adequate supply of air for combustion and ventilation is
provided through infiltration. However, if the Burner is used in a small
room where less than 5.7m
[200ft
3
1000 BTU per hour of appliance rating (considering the maximum Burner
setting), the door(s) to adjacent room(s) should be kept open or a window
to the outside should be opened at least 25.4mm [1in] to guard against
potential build up of indoor air pollution. Do not install or operate in a
bathroom or any other small room.
Model
Minimum room size
BK5
The room cannot be less than 70m
BK3
The room cannot be less than 45m
BK2UL
The room cannot be less than 45m
XL900
The room cannot be less than 110m
XL700
The room cannot be less than 90m
XL500
The room cannot be less than 80m
XS340
The room cannot be less than 45m
AB8
The room cannot be less than 105m
AB3
The room cannot be less than 40m
Ventilation requirements must be adhered to at all times.
WARNING
The DIN 4734 requires that the combined rate of consumption of all
Burners in a room cannot exceed .50 L/hr which means that only one
(1) BK3 can be used in any room, regardless of room size, under DIN
4734.
www.ecosmartfire.com
] of air space is provided for each
3
3
3
] per burner.
[2472ft
3
[1589ft
3
] per burner.
3
[1589ft
3
] per burner.
3
3
] per burner.
[3884ft
3
[3178ft
3
] per burner.
3
[2825ft
3
] per burner.
3
[1589ft
3
] per burner.
] per burner.
3
[3708ft
3
3
[1413ft
3
] per burner.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ab seriesBk seriesXs series

Inhaltsverzeichnis