Clearances & Installation
Ensure that the mouth of the flame is positioned a minimum of 1500mm [59.1in] away from curtains,
flammable materials and other sources of ignition. Be aware of drafts. The floor must be level and the
Burner positioned on a flat surface. The Burner must only be placed into non combustible materials and
must be installed in accordance with the outlined safety requirements and clearances. Please send your
drawings to your local representative to confirm the setting complies with the manufacturer's requirements
prior to installation.
Burner Clearances
EcoSmart™ Fire Burners can be installed into two (2) types of settings.
A. Those that are encased by non-combustible materials similar to that
which you would find in a traditional masonry set up. We refer to this
installation type as "WITHIN A FIREBOX SETTING"
A. INSERTING WITHIN A FIREBOX SETTING
BURNERS
Firebox Width (X)
BK SERIES
650mm [25.6in]
XL900
1200mm [47.2in]
XL700
1000mm [39.4in]
XL500
800mm [31.5in]
XS340
450mm [17.7in]
AB8
650mm [25.6in]
AB3
400mm [15.7in]
B. INSERTING WITHOUT A FIREBOX SETTING
BURNERS
Overhead (Y)
BK SERIES
1500mm [59.1in]
XL900
1500mm [59.1in]
XL700
1500mm [59.1in]
XL500
1500mm [59.1in]
XS340
1500mm [59.1in]
AB8
1500mm [59.1in]
AB3
1500mm [59.1in]
*WARNING! Fire hazard. The rear wall should be non-combustible. If it is combustible, you must allow at
least 600mm (23.6in.) clearance between the wall and the rear of the EcoSmart™ Fire.
Custom made fireboxes must:
- Be made out of a non-combustible material such as stainless steel
- Be constructed to accommodate a Top Tray
- Have built in spacers of 20mm [0.8in] on all sides to ensure that it does not sit directly against any
combustible materials and an air gap is incorporated for insulation around the box construction. The use of
insulation wool is permitted.
www.ecosmartfire.com
Firebox Depth (Z)
Overhead (Y)
365mm [14.4in]
650mm [25.6in]
350mm [13.8in]
500mm [19.7in]
350mm [13.8in]
500mm [19.7in]
350mm [13.8in]
500mm [19.7in]
300mm [11.8in]
450mm [17.7in]
450mm [17.7in]
800mm [31.5in]
350mm [13.8in]
500mm [19.7in]
Nearest Combustible
Front (B1)
Radius
45mm [1.8in]
600mm [23.6in]
50mm [2.0in]
600mm [23.6in]
50mm [2.0in]
600mm [23.6in]
50mm [2.0in]
600mm [23.6in]
45mm [1.8in]
600mm [23.6in]
45mm [1.8in]
600mm [23.6in]
45mm [1.8in]
600mm [23.6in]
B. Those that are not encased by non-combustible materials and set
up in a more modern setting without sides or a top. We refer to this
installation type as "WITHOUT A FIREBOX SETTING"
Rear (B2)
Front (B1)
30mm [1.2in]
45mm [1.8in]
40mm [1.6in]
50mm [2.0in]
40mm [1.6in]
50mm [2.0in]
40mm [1.6in]
50mm [2.0in]
65mm [2.6in]
45mm [1.8in]
30mm [1.2in]
45mm [1.8in]
30mm [1.2in]
45mm [1.8in]
(B2)
Rear
(A)
(Only if Non-combustible)*
30mm [1.2in]
40mm [1.6in]
40mm [1.6in]
40mm [1.6in]
65mm [2.6in]
30mm [1.2in]
30mm [1.2in]
Z
Y
A
B2
B1
A
X
e.g BK SERIES
Y
A
B2
min
20mm
[0.8]
B1
A
Spacers
FRONT VIEW
e.g BK SERIES