Elektro-Automatik PSI 9000 2U Bedienungsanleitung Seite 143

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

IF Level 1
Node Address
Function Tag
Location Tag
Installation Date
Description
IF Level 1
-
IF Level 1
Level 2
IP Settings
DHCP
Manual
DNS 1
DNS 2
Port
Host name
Domain name
SMTP
Server IP
Settings
Username
Password
Function Tag
String input box for a user-definable text which describes the Profinet slave function tag.
Max. length: 32 characters
Location Tag
String input box for a user-definable text which describes the Profinet slave location tag.
Max. length: 22 characters
Station Name
String input box for a user-definable text which describes the Profinet station name.
Max. length: 54 characters
Description
String input box for a user-definable text which describes the Profibus slave.
Max. length: 54 characters
Installation Date String input box for a user-definable text which describes the Profibus slave installation
date tag. Max. length: 40 characters
IF Level 1
Description
Node Address
Adjustment of the GPIB node address (only with option 3W installed) in the range 1...30
EA Elektro-Automatik GmbH
Helmholtzstr. 31-33 • 41747 Viersen
Germany
Description
Selection of the Profibus or node address of the device within range 1...125 via
direct input
String input box for a user-definable text which describes the Profibus slave function
tag. Max. length: 32 characters
String input box for a user-definable text which describes the Profibus slave location
tag. Max. length: 22 characters
String input box for a user-definable text which describes the Profibus slave instal-
lation date tag. Max. length: 40 characters
String input box for a user-definable text which describes the Profibus slave.
Max. length: 54 characters
Description
The baud rate is selectable, other serial settings can't be changed and are defined
like this: 8 data bits, 1 stop bit, parity = none
Baud rates: 2400, 4800, 9600, 19200, 38400, 57600, 115200
Level 3
Description
The IF allows a DHCP server to allocate an IP address, a subnet
mask and a gateway. If no DHCP server is in the network then net-
work parameters will be set as defined in point "Manual"
IP
This option is activated by default. An IP address can be maually
allocated.
Gateway Here a gateway address can be allocated if required..
Subnet
Here a subnet mask can be defined if the default subnet mask is
not suitable.
Here the addresses of the first and second Domain Name Servers
(DNS) can be defined, if needed. A DNS is only necessary if the
device has Internet access and should call Internet URLs, e.g. an
internal eMail system, in order to send an eMail.
Range: 0...65535. Default ports:
5025 = Modbus RTU (for Modbus & SCPI)
Free choice of host name (default: Client)
Free choice of Domain (default: Workgroup)
Mail server address, used to send eMails via this mail server, in
order to e.g. report an alarm.
Login to Mailserver, Username
Login to Mailserver, Password
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
PSI 9000 2U Series
www.elektroautomatik.de
ea1974@elektroautomatik.de
Page 49