Herunterladen Inhalt Inhalt Diese Seite drucken

Elektro-Automatik PSI 9000 2U Bedienungsanleitung Seite 106

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

PSI 9000 2U Series
1000 W
AC Input
Voltage range
Connection
Frequency
Fusing
Leak current
Power factor
DC Output
Max. output voltage U
Max
Max. output current I
Max
Max. output power P
Max
Overvoltage protection range
Overcurrent protection range
Overpower protection range
Output capacitance (std. model)
Output capacitance (HS model)
Temperature coefficient for set
values Δ/K
Voltage regulation
Adjustment range
Accuracy
(at 23 ± 5°C)
(1
Line regulation at ±10% ΔU
Load regulation at 0...100% load
Rise time 10...90%
Settling time after load step
Display: Resolution
Display: Accuracy
(3
Ripple
(2
Remote sensing compensation
Output voltage fall time (at no load)
after switching DC output off
Current regulation
Adjustment range
Accuracy
(at 23 ± 5°C)
(1
Line regulation at ±10% ΔU
Load regulation at 0...100% ΔU
Ripple
(2
Display: Resolution
Display: Accuracy
(3
Power regulation
Adjustment range
Accuracy
(at 23 ± 5°C)
(1
Line regulation at ±10% ΔU
Load reg. at 10-90% ΔU
OUT
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz
(3 The display error adds to the error of the related actual value on the DC output
EA Elektro-Automatik GmbH
Page 12
Helmholtzstr. 31-33 • 41747 Viersen
Germany
PSI 9360-10
90...264 V AC
1ph,N,PE
45-65 Hz
T16 A
< 3.5 mA
~ 0.99
360 V
10 A
1000 W
0...396 V
0...11 A
0...1100 W
330 μF
20 μF
Voltage / current: 100 ppm
0...360 V
< 0.1% U
Nom
< 0.02% U
AC
Nom
< 0.05% U
Nom
Max. 30 ms
< 1.5 ms
See section „1.9.6.4. Resolution of the displayed values"
≤ 0.2% U
Nom
< 210 mV
PP
< 59 mV
RMS
Max. 5% U
Nom
Down from 100% to <60 V: less than 10 s
0...10 A
< 0.2% I
Nom
< 0.05% I
AC
Nom
< 0.15% I
OUT
Nom
< 1.6 mA
RMS
See section „1.9.6.4. Resolution of the displayed values"
≤ 0.2% I
Nom
0...1000 W
< 1% P
Nom
< 0.05% P
AC
Nom
* ΔI
< 0.75% P
OUT
Nom
Model 2U
PSI 9500-06
90...264 V AC
1ph,N,PE
45-65 Hz
T16 A
< 3.5 mA
~ 0.99
500 V
6 A
1000 W
0...550 V
0...6.6 A
0...1100 W
120 μF
15 μF
0...500 V
< 0.1% U
Nom
< 0.02% U
Nom
< 0.05% U
Nom
Max. 30 ms
< 1.5 ms
≤ 0.2% U
Nom
< 190 mV
PP
< 48 mV
RMS
Max. 5% U
Nom
0...6 A
< 0.2% I
Nom
< 0.05% I
Nom
< 0.15% I
Nom
< 0.5 mA
RMS
≤ 0.2% I
Nom
0...1000 W
< 1% P
Nom
< 0.05% P
Nom
< 0.75% P
Nom
Fon: +49 2162 / 3785-0
Fax: +49 2162 / 16230
PSI 9750-04
90...264 V AC
1ph,N,PE
45-65 Hz
T16 A
< 3.5 mA
~ 0.99
750 V
4 A
1000 W
0...825 V
0...4.4 A
0...1100 W
40 μF
9 μF
0...750 V
< 0.1% U
Nom
< 0.02% U
Nom
< 0.05% U
Nom
Max. 30 ms
< 1.5 ms
≤ 0.2% U
Nom
< 212 mV
PP
< 60 mV
RMS
Max. 5% U
Nom
0...4 A
< 0.2% I
Nom
< 0.05% I
Nom
< 0.15% I
Nom
< 0.3 mA
RMS
≤ 0.2% I
Nom
0...1000 W
< 1% P
Nom
< 0.05% P
Nom
< 0.75% P
Nom
www.elektroautomatik.de
ea1974@elektroautomatik.de

Werbung

Kapitel

Inhaltsverzeichnis
loading