Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Battery - PeakTech 1610 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für 1610:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Messfolge
2 x pro Sekunde, 20 x pro Sek. analoge
Balkengrafik (P 1625)
2 x pro Sekunde (P 1610, P 1615)
Abschaltautomatik P 1610: 30 Minuten / P 1615: 35 Minuten /
P 1625: 20 Minuten
Spannungsver-
sorgung
9 V-Blockbatterie
Max. Leiterdurch-
messer
30 mm
Betriebstemp-
bereich
-10...50° C bei max. 85 % R.H.
Lagertemp.-
bereich
-30...+60° C bei max. 85 % R.H.
max. Betriebshöhe 3.000 m ü.M.
Abmessungen
80 (B) x 229 (H) x 40 (T) mm
Gewicht
300 g
3.1. Maximal zulässige Eingangswerte
Funktion
A AC, D CA (P 1615, P 1625)
V DC, V AC
Widerstand, Diode, Durchgangs-
prüfung,
Frequenz,
Arbeitszyklus, Kapazität
Temperatur (° C/° F)
Max. Eingang
1000 A
600 V DC/AC
250 V DC/AC
60 V DC/24 V AC
-5-
3. Connect the K-type probe into the meter adaptor and measure
the temperature of the apparatus or area required.
4. Read the temperature directly from the display.
5. To change the measuring unit from ° C to ° F press the MODE-
button to select the ° F unit (P 1610 / P 1625).

7. Replacing the battery

WARNING! To avoid electrical shock, disconnect the test leads and
any input signals before replacing the battery. Replace only with
same type of battery.
This meter is powered by a NEDA type 1604 or equivalent 9 V-
battery. When the meter displays the battery symbol the battery
must be replaced to maintain proper operation. Use the following
procedure to replacing the battery.
1. Disconnect test leads from any live source, turn the rotary switch
to OFF and remove the test leads from the input terminals.
2. The battery cover is secured to the bottom case by a screw.
Using a Philips-head screwdriver, remove the screw from the
battery cover and remove the battery cover.
3. Remove the battery and replace with a new equivalent 9 V-
battery.
4. Replace the battery cover and reinstall the screw.
Note: Batteries which are used up, dispose duly. Used up batteries
are hazardous and must be given in the for this being supposed
collective container.