4.6. Kapazitätsmessungen
Modell
Bereich
Auflösung
P 1610
40 nF
10 pF
400 nF
100 pF
4 µF
40 µF
10 nF
100 µF
100 nF
P 1615
40 nF
10 pF
400 nF
100 pF
4 µF
40 µF
10 nF
100 µF
100 nF
P 1625
4 nF
40 nF
10 pF
400 nF
100 pF
4 µF
40 µF
10 nF
400 µF
100 nF
4 mF
40 mF
10 µF
Überlastschutz: 250 V AC/DC
Genauigkeit
± 5,0% v.M. + 100 dgt
± 3,0% v.M. +
1 nF
± 3,5% v.M. +
± 5,0% v.M. +
± 5,0% v.M. + 100 dgt
± 3,0% v.M. +
1 nF
± 3,5% v.M. +
± 5,0% v.M. +
1 pF
± 5,0% v.M. + 30 dgt
± 5,0% v.M. + 20 dgt
1 nF
± 3,0% v.M. +
± 4,0% v.M. + 10 dgt
1 µF
± 4,5% v.M. + 10 dgt
± 5,0% v.M. + 10 dgt
-9-
6. After completing the measurement, turn off power to the
circuit/device under test, discharge all capacitors and disconnect
the meter test leads.
5 dgt
5 dgt
6.2. Current Measurements
5 dgt
WARNING! These Snap-arounds are designed to take current
measurements on circuits with a maximum voltage difference of
5 dgt
600 V AC between any conductor and ground potential. Using the
5 dgt
snap-around for current measurements on circuits above this
voltage may cause electric shock, instrument damage and/or
5 dgt
damage to the equipment under test. Before measuring current
make certain that the test leads are removed from the instrument.
The snap-around is overload protected up to 600 V AC for up to 1
5 dgt
Min. Do not take current readings on circuits where the maximum
current potential is not known. Do not exceed the maximum current
that this instrument is designed to measure.
1. Set Function Switch to 40 A, 400 A or 1000A AC or 40A, 400A
or 1000A DC (P 1615 / P 1625).
2. Press the trigger to open the transformer jaws and clamp them
around a conductor. Jaws should be completely closed before
taking a reading.
3. The most accurate reading will be obtained by keeping the
conductor across centre of the transformer jaws.
4. The reading will be indicated on the display.
5. Reduce the range setting if too high until a satisfactory best
resolution reading it obtained.