PeakTech 1610 Bedienungsanleitung Seite 15

Vorschau ausblenden Andere Handbücher für 1610:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.9. Temperaturmessungen
Modell
Bereich
Auflösung
P 1610
-50... 400° C
0,1 ° C
400...1000° C 1
-58... 400° F 0,1 ° F
400...1832° F 1
P 1615
-20...1000° C
1
-4... 1832° F
1
P 1625
-40...1000° C
1
-40...1832° F
1
Überlastschutz: 60 V DC / 24 V AC
4.10. Durchgangsprüfung
Modell
Tonsignal-Grenzwert
P 1610
< 100 Ω
P 1615
< 100 Ω
P 1625
< 35 Ω
Überlastschutz: 250 V AC/DC
4.11. Diodentest
Modell
Teststrom
P 1610
P 1615
0,3 mA
P 1625
Überlastschutz: 250 V AC/DC
Genauigkeit
± 3,0% v.M. + 5 dgt.
° C
± 3,0% v.M. + 7 dgt.
° F
° C
± 3,0% v.M. + 5 dgt.
° F
± 3,0% v.M. + 7 dgt.
° C
± 2,5% v.M. + 3 dgt.
° F
± 2,5% v.M. + 5 dgt.
Teststrom
< 1 mA
Spannung bei offener Last
1,5 V
-11-
Zero Button (P 1625)
Press ZERO button to enter the relative mode, the ZERO ∆
annunciator turns on, zero the display and store the displayed
reading as a reference value. Press and hold down the ZERO button
for 2 seconds to exit the relative mode.
In the relative mode the value shown on the LCD is always The
difference between the stored reference value and the present
reading. For example, if the reference value is 24.000 V and the
present reading is 12,50 V the display will indicate –11,50 V. If the
new reading is the same as the reference value, the display will be
zero. This feature also is made as DCA ZERO adjustment.
Transformer jaws
Pick up the AC or DC current flowing through the conductor. The "+"
marking on the jaw indicates direction of DC Current existing on the
conductor being tested which follows forward and vertically with
jaws, and reading shown on display is positive.
Peak Button (P 1625)
This measurement function is used to measure the peak value of a
signal. It is useable with AC current measurements. To use this
function select the function and range and press the peak hold
switch. When this is done, the "P" will appear in the display. Next, by
inputting a signal, the peak hold function operates. This peak hold
value is held in digital memory for a long period. To cancel the
function press the peak hold switch once again.
Trigger
Press the lever to open the transformer. When the lever is released,
the jaws will close again.
ZERO (P 1615)
Before taking DCA measurements, push and hold the ZERO button
until display indicates zero. This button does not work on other
functions/ranges.