4.3. Gleichstrom
Modell
Bereich
Auflösung
P 1615
40 A
10 mA
400 A
100 mA
1000 A
1
P 1625
40 A
10 mA
400 A
100 mA
1000 A
1
Überlastschutz: 1000 A
PeakTech 1615: Positionsfehler ± 1% v. Messwert
4.4. Wechselstrom
Modell
Bereich
Auflösung
P 1610
40 A
10 mA
400 A
100 mA
1000 A
1
P 1615
40 A
10 mA
400 A
100 mA
1000 A
1
P 1625
40 A
10 mA
(Echt-
400 A
100 mA
Effektiv)
1000 A
1
Überlastschutz: 1000 A
PeakTech 1610 / 1615: Positionsfehler ± 1% v. Messwert
Frequenz-Bereich: 50/60 Hz
Genauigkeit
± 2,8% v.M. + 10 dgt.
± 2,8% v.M. + 5 dgt.
A
± 3,0% v.M. + 5 dgt.
± 2,8% v.M. + 10 dgt.
± 2,8% v.M. + 8 dgt.
A
± 3,0% v.M. + 8 dgt.
Genauigkeit
± 2,5% v.M. + 10 dgt.
± 2,5% v.M. + 5 dgt.
A
± 3,0% v.M. + 4 dgt.
± 3,0% v.M. + 10 dgt.
± 3,0% v.M. + 5 dgt.
A
± 3,0% v.M. + 5 dgt.
± 2,8% v.M. + 10 dgt.
± 2,8% v.M. + 8 dgt.
A
± 3,0% v.M. + 8 dgt.
-7-
6.4. Continuity testing
)
)
1. Select the
)
position by turning the rotary selector switch.
°
2. Follow step 2 and 4 as for resistance measurements.
3. An audible tone will sound for resistance less than approx. 35 Ω
(P 1625) or 100 Ω (P 1610/P 1615). After all measurements are
completed, disconnect the test leads from the circuit and from
the DCM input terminals.
6.5. Diode testing
CAUTION!
Measurements must only be made with the circuit power OFF.
1. Set the rotary selector switch to the
2. Follow steps 2 and 4 as for resistance measurements.
3. The red test lead should be connected to the anode and the
black lead to the cathode. For a silicon diode, the typical forward
voltage should be about 0,7 V or 0.4 V for a germanium diode.
4. If the diode is reverse biased or there is an open circuit the
display shows "OL".
6.6. Capacitance measurement
1. Turn off power to the device under test and discharge all
capacitors.
2. Discharge all voltage from the capacitor before measuring its
capacitance value.
Note: A safe way to discharge a capacitor is to connect a 100
kΩ resistor across the two capacitor leads.
3. Set the rotary selector switch to the capacitance range.
- position.