6. How to make measurements

Before making any measurements read safety precautions. Always
examine the instrument and accessories used with the instrument for
damage, contamination (excessive dirt, grease, etc) and defects.
Examine the test leads for cracked or frayed insulation and make
sure the lead plugs fit snugly into the instrument terminals. If any
abnormal
conditions
exist,
measurements.
6.1. Voltage measurements
1. Turn off power to the device under test and discharge all
capacitors.
2. Plug the black test lead into the COM input jack on the meter and
connect the test lead tip to a grounded point (the reference point
for measurement of voltage).
3. Select the desired AC voltage range or DC voltage range. If the
magnitude of the voltage to be measured is unknown always
start with the highest range.
WARNING!
To avoid possible electric shock, instrument damage and/or
equipment
damage,
do
not
measurements if the voltage is above 600 V AC/DC are the
maximum voltages that this instrument is designed to measure. The
"COM" terminal potential should not exceed 600 V measured to
ground.
4. Plug the red test lead into the V/Ω-Input jack on the meter and
connect the circuit where a voltage measurement is required.
Voltage is always measured in parallel across a test point.
5. Turn on power the circuit/device to be measured and make the
voltage measurement reduce the range setting if set too high
until a satisfactory reading is obtained.
do
not
attempt
to
make
attempt
to
take
any
voltage
-41-
4.7. Frequenzmessungen
Modell
Bereich
P 1610
5
50
500
5 kHz
50 kHz
any
500 kHz 100
5 MHz
10 MHz
P 1615
5
50
500
5 kHz
50 kHz
100 kHz 100
P 1625
4 kHz
Überlastschutz: 250 V AC/DC
4.8. Arbeitszyklus
Modell
Bereich
P 1610
0,5...99,0 %
Pulsweite: 100 µs – 100 ms
P 1615
0,5...99,0 %
Pulsweite: 100 µs – 100 ms
Frequenz: 5 Hz – 100 kHz
Überlastschutz: 250 V AC/DC
Auflösung
Genauigkeit
Hz
1 mHz
± 1,5%v.M.+ 5 dgt
Hz
10 mHz
Hz 100 mHz
± 1,2% v.M.+ 2 dgt
1
Hz
10
Hz
Hz
1 kHz
±1,5%v.M.+10dgt
10 kHz
Hz
1 mHz
± 1,5% v.M.+ 5 dgt
Hz
10 mHz
Hz 100 mHz
± 1,2% v.M.+ 2 dgt
1
Hz
10
Hz
Hz
1
Hz
± 1,5% v.M.+ 2 dgt
Auflösung Genauigkeit
0,1%
± 1,2% v.M.+2 dgt.
0,1%
± 1,2% v.M.+2 dgt.
-10-
Empfindlich-
keit
10 V
min.
eff
10 V
min.
eff
5 V
min.
eff