Detector for safety edges ("USA")
Evaluator
Configuration
Safety edge with 1,2 kΩ closing resistance without checking
Safety edge with 1,2 kW closing resistance with checking
The.safety.edge.is.checked.during.every.closing.movement:.after.the.pre-end-
limit. switch. has. been. actuated,. the. safety. edge. has. to. be. actuated. within. 2.
seconds.(positive.testing).
Safety edge with 8,2 kW closing resistance without checking
Safety edge with 8,2 kΩ closing resistance with checking
The.safety.edge.is.checked.during.every.closing.movement:.after.the.pre-end-
limit. switch. has. been. actuated,. the. safety. edge. has. to. be. actuated. within. 6.
seconds.(positive.testing).
Optical safety edge manufactured by Fraba
Note
In the case of pneumatic safety edges (testing) a pre-end-limit switch (Item
No. 4932 100 012 0) must always be connected.
These. settings. are. only. possible. if. the. plug-in.
evaluator.for.safety.edges.is.plugged.in.
For. safety. reasons. pneumatic. safety. edges. are.
checked. at. the. end. of. every. downward. move-
ment.
DIP-switch
safty.edge
de
en
fr
nl