Configuration; Factory Settings; Operating Mode - Becker Beck-O-Tronic 4 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Beck-O-Tronic 4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Factory settings

Factory setting for dead man's operating mode:
ON
DIP
1
4
2
3
5
6
7
8
Factory setting for automatic operating mode
(only with safety edge evaluator):
ON
DIP
1 2 3
1
2
3
4
5
6
7
8

Operating mode

Setting mode:
End. position. recognition. and. running. time. monitoring. are. deactivated.. The.
BECK-O-TRONIC.4.does.not.remove.the.power.from.the.tubular.motor.when.an.
end.position.has.been.reached..Thus,.the.door.system.can.be.adjusted.under.
power..This.means.that.the.door.system.immediately.follows.the.settings.of.the.
limit.switch..To.remove.power.press.the.STOP.button.
Attention
The setting mode is suitable for tubular motors with mechanical limit switch-
ing.
When all settings have been completed, DIP switch 1 has to be set to OFF
(door mode). Operation in setting mode is not permitted!
Door mode:
The.BECK-O-TRONIC.4.control.device.is.on.standby..End.position.detection.
and.running.time.monitoring.have.been.activated.

Configuration

With. the. 8. DIP. switches. you. can. configure. the.
BECK-O-TRONIC. 4. according. to. your. own. re-
quirements:
•. Operating.mode
•. Safety.edge.system
•. Yard.light.or.advance.warning.lamp
•. Automatic.closing
DIP-switch
de
en
fr
nl
25