e) Switching the device on and off
• To switch on the endoscope basic device, push the on/off button A16 for 3 to 5 seconds.
Then release the button. The device will start about one second later and indicate this in the display.
When starting is completed, the device is in preview mode. This means that the current camera picture, the
set date (D1) and the time (D2), as well as the meter display (D3) are shown.
At the lower right of the display, you will also see the display for the battery charge(D5). If the battery charge
is too low, charge the rechargeable battery before continuing.
A bar (D6) is shown just below, indicating the remaining capacity of the memory card. To show the bar again,
push the button "Esc" (A15).
• To switch off the endoscope basic device, push the on/off button A16 again for 3 to 5 seconds. Once the display
goes out, the device is off.
• If no input is made for some time, the endoscope will switch off on its own. The time can be set in the menu.
Observe chapter 9. c).

f) Setting the camera lighting

To be able to use the endoscope in absolutely dark areas as well, the BS-1500T has an integrated dial for the LED
lighting installed in the camera head.
• Push the button A11 (button with the sun and the arrow up) to increase brightness.
• To reduce brightness, push the button A12 (button with the sun and the arrow down).
• Set the lighting so that the picture displayed is recognisable well.
In narrow tubes or similar, it may be of advantage to reduce lighting slightly to prevent reflections and too
bright pictures.