Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Maintenance And Cleaning - VOLTCRAFT BS-25HR Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation

Hold the camera neck and head only in voltage-free liquids. Do not submerge the
camera neck past the marking "MAX Water Level".
The endoscope is suited for inspection only in voltage-free systems. The camera
head is made of metal and can cause short-circuiting. For safety reasons, make
sure all system components are voltage-free before inspection.
Avoid heavy mechanical loads and/or vibrations. Do not exceed the minimum
bending radius of 45 mm.
a) Turning on/off
• Press the
button (5) to turn on the product. The camera image is shown on the monitor (3).
• Press the
button again to turn off the product. The monitor goes out.
b) Camera light
• Four white LEDs with 6 adjustable lighting levels are built into the camera head (2).
• Repeatedly press the ↑ button (6) to increase the LED lighting level.
• Repeatedly press the ↓ button (4) to decrease the LED lighting level or to turn off the light.
• While adjusting the lighting level, a bar graph appears at the bottom middle of the monitor (3)
to indicate the set lighting level.
Set the light so that the image is neither over- nor underexposed.
c) Monitor backlight
• Simultaneously press and hold the ↑ (6) und ↓ (4) buttons to adjust the monitor (3) backlight
in 3 levels.
• Release both buttons when the desired level is reached.
d) Zoom
• The image can be magnified in 2 levels:
- 1.5x magnification
- 2x magnification
• Press and hold the ↓ (4) button. The monitor (3) shows one of three indicators:
- 1.5x (1.5x magnification)
- 2.0x (2x magnification)
- 1.0x (no magnification)
e) Rotating the image
Press and hold the ↑ (6) button to rotate the image 180°.
f) Attachments
• Carefully open the attachment's fastening ring. Fasten the attachment to the narrow
indentation beneath the camera head. Do not bend the fastening ring too much to open it to
prevent it from breaking.
• Make sure that the attachment's fastening ring is closed before use. Otherwise you run the
risk of losing the attachment.
• The mirror attachment (7) can extend the endoscope's field of view into areas that are difficult
to access for the camera head.
• The magnet attachment (8) can be used to locate lost metallic objects.
• The hook attachment (9) can be used to take hold of small objects.

Maintenance and cleaning

• Besides occasional cleaning, the device is maintenance-free. To clean the device, use a soft,
anti-static and lint-free cloth.
• Do not use any abrasive or chemical cleaners.
• After use in liquids, always thoroughly rinse the camera neck with clean water and dry before
storing the product in the case.
• To clean the camera lens, use a small brush or cotton swabs.
Disposal
a) Product
Electronic devices are recyclable waste and must not be disposed of in the
household waste. At the end of its service life, dispose of the product in accordance
with applicable regulatory guidelines.
Remove any inserted (rechargeable) batteries and dispose of them separately from
the product.
b) (Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used
(rechargeable) batteries. Disposing of them in the household waste is prohibited.
Contaminated (rechargeable) batteries are labelled with this symbol to indicate that
disposal in the domestic waste is forbidden. The designations for the heavy metals
involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead (name on (rechargeable)
batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your
municipality, our stores or wherever (rechargeable) batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the
environment.
Technische Daten
Power supply ................................ 4 x 1.5 V battery type AA (not included)
Monitor .......................................... 5.8 cm (2.3") TFT
Resolution ..................................... 960 x 240 pixels (monitor)
640 x 480 pixels (camera)
Camera light ................................. 4 white LEDs
White balance ............................... automatic
Exposure ...................................... automatic
Field of view .................................. 54º
Focus depth .................................. ≥3 cm
Operating conditions ..................... 0 to +45 ºC, 15 – 85 % RH
Storage conditions ........................ -10 to +50 ºC, 15 – 85 % RH
Bending radius .............................. min. 45 mm
Gooseneck length ......................... 88 cm ±2 cm
Gooseneck Ø ................................ 6.5 mm
Camera head Ø ............................ 8 mm
Dimensions (W x H x D) ............... 86 x 1105 x 60 mm
Weight .......................................... approx. 313 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
This publication represent the technical status at the time of printing.
Copyright 2017 by Conrad Electronic SE.
*1529791_v1_0217_02_jh_m_en_(1)

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis