"O-Ld" appears when exceeding the measuring capacity. In such a case, remove the
item from the scale immediately in order to avoid damage to the scale.
Selecting measuring unit
• The hanging scale supports weighing in kilogram (kg) and British pound (lb).
• When the scale is turned on, press the UNIT button (3). Each time pressing the button will
select another measuring unit. The selected unit appears with a triangle on the right edge of
the display. The unit selected last will be saved after turning off the scale.
Weighing
• Turn on the scale and wait for "0.0" to be displayed.
• Carefully attach the item to be weighed to the S hook (9) without too much jerking. Avoid
swinging movements and, if necessary, bring the item to a complete halt.
• Wait for approx. 5 seconds until the reading has stabilized. The measuring result will be
displayed.
• The measuring result can be frozen for easy reading by pressing the HOLD button (2).
When the HOLD function is activated, "H" appears in the display. Remove the item from the
hook immediately after measuring. The reading is kept for approx. 10 seconds or until you
press the HOLD button again or turn off the scale.
• Press and hold the ON/OFF button for approx. 3 seconds to turn off the scale.
Weighing with weighing container (tare function)
• Weighing containers can be used for weighing liquids or bulk material. In order to exclude
the weight of such weighing containers during measuring, use the tare function. Weighing
container and item to be weighed must not exceed the total weight of 100 kg.
• Turn on the scale and wait for "0.0" to be displayed.
• Attach the empty weighing container to the hook (9) and wait for the reading to stabilize.
• Briefly press the TARE button (4). The display will be reset to zero, thereby excluding the
weight of the weighing container from the subsequent measuring.
• Remove the weighing container and fill it with the items to be weighed.
• Attach the filled weighing container to the hook (9). Dynamic measuring by adding more
quantity is not permitted, as this would cause measuring errors.
• Wait for approx. 5 seconds for the reading to stabilize. The measuring result will be
displayed.
• The measuring result can be frozen for easy reading by pressing the HOLD button. When
the HOLD function is activated, "H" appears in the display. Remove the item from the hook
immediately after measuring. The reading is kept for approx. 10 seconds or until you press
the HOLD button again or turn off the scale.
• Press and hold the ON/OFF button for approx. 3 seconds to turn off the scale.
Automatic power-off
The hanging scale will turn off automatically after approx. 2 minutes in order to save energy
and extend battery use. Press the ON/OFF button (4) to turn the scale on again.

MAINTENANCE AND CLEANING

• Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as
they can cause damage to the housing and malfunctioning.
• Except for occasional cleaning and battery replacement, this product does not require any
maintenance.
• Use a soft, slightly damp, anti-static and lint-free cloth for cleaning.
DISPOSAL
a) Product
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the relevant
statutory regulations.
Remove any inserted batteries and dispose of them separately from the product.
b) Batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries.
Disposing of them in the household waste is prohibited.
Contaminated batteries are labelled with this symbol to indicate that disposal in the
domestic waste is forbidden. The designations for the heavy metals involved are:
Cd = Cadmium, Hg = Mercury, Pb = Lead (name on batteries, e.g. below the trash
icon on the left).
Used batteries can be returned to collection points in your municipality, our stores or
wherever batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of the environment.

TECHNICAL DATA

Power supply ............................................... 2 x 3 V lithium battery, type CR2032
Weighing range ........................................... 2 - 100 kg / 4 - 220 lb
Resolution "d" .............................................. 100 g / 0.2 lb
Tolerance ..................................................... ± 500 g / ± 1.1 lb
Overload display .......................................... O-Ld
Unit of weight ............................................... kg, lb
Measurement sensor ................................... wear-free strain gauge
Automatic power-off ..................................... approx. 2 minutes
Loop diameter .............................................. 15 mm
Operating temperature ................................ 10 to 30 °C
Operating humidity ...................................... max. 80% RH, non-condensing
Storage temperature .................................... 0 to 55 °C
Storage humidity .......................................... max. 80% RH, non-condensing
Dimensions (W x H x D) .............................. 70 x 150 x 30 mm
Weight (scale) without accessories ............. approx. 175 g
Legal notice
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing
systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the
time of printing.
© Copyright 2015 by Conrad Electronic SE
V2_0515_02-HK

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis