Refill detergent
DANGER
Risk of injury!
– Use Kärcher products only.
– Under no circumstances fill solvents
(petrol, aceton, diluting agent etc.)
– Avoid eye and skin contact.
– Observe safety and handling instruc-
tions by the detergent manufacturer.
Kärcher offers an individual cleaning
and care appliances program.
Your dealer will consult you gladly.
 Refill detergent.

Water connection

For connection values refer to technical
specifications.
 Attach supply hose (minimum length
7.5 m, minimum diameter 3/4") to the
water supply set by means of a hose
clamp.
 Connect the supply hose to the water
connection point of the machine and at
the water supply point (for e.g. a tap).
Note: The supply hose and the hose clamp
are not included in the scope of delivery.
Suck in water from vessel
If you want to suck in water from an exter-
nal vessel, the following modification is
necessary:
Figure 6
 Remove the two screws on the burner
casing.
Figure 7
 Unscrew the back wall and remove it.
Figure 8
 Remove water connection from the fine
filter.
 Unscrew the fine filter from the pump
head.
 Remove the system care reservoir.
Figure 9
 Unscrew the top supply hose to the
swimmer container.
 Connect the top supply hose at pump
head.
 Replug the rinse line of the detergent
dosing valve to blind plugs.
 Connect suction hose (minimum diame-
ter 3/4") with filter (accessory) to the
water connection point.
– Max. suck height: 0.5 m
Until the pump sucked in water, you should:
 Set the pressure/quantity regulation at
the pump unit to maximum quantity.
 Close the dosing valve for the detergent.
DANGER
Risk of personal injury or damage! Never
suck in water from a drinking water contain-
er. Never suck in liquids which contain sol-
vents like lacquer thinner, petrol, oil or unfil-
tered water. The sealings within the device
are not solvent resistant. The spray mist of
solvents is highly inflammable, explosive
and poisonous.
 Assembly in reverse order.
Note: Ensure that the solenoid valve cable
on the reservoir of the system care is not
pinched.

Power connection

– For connection values, see technical
data and type plate.
– The electrical connections must be
done by an electrician according to IEC
60364-1.
DANGER
Risk of injury on account of electric shock!
– Unsuitable electrical extension cables
can be hazardous. Only use electrical
extension cables outdoors which have
been approved and labelled for this pur-
pose and have an adequate cable
cross-section.
– Always unwind extension lines com-
pletely.
– The plug and coupling of the extension
cable used must be watertight.
ATTENTION
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal data) is not to be exceeded. In case of
confusion regarding the power impedance
present on your connection, please contact
your utilities provider.
– 5