Hints and tips
Every time the cleaner is taken out of the water, the filter cleaner
must be cleaned.
Make sure the pH value of the water is between 7.0 and 7.2.
Make sure the water temperature is between 12°C and 32°C.
After every clean, the drive train must be thoroughly cleaned to en-
sure the same level of grip on the next clean.
After pressing the "Power Off" button, the "Power On" button cannot
be pressed for 30 seconds.
We recommend keeping the cleaner between 5°C and 40°C in a
shaded, well ventilated place. The mains cable should be coiled
around the cable holder for storage. (The floats must not be pushed
along the cable to ensure the cable floats properly in the water.)
Avoid direct sunlight at all times.
We recommend attaching the operating unit with a safety rope, to
avoid any risk of the power pack being pulled into the pool.
Before use, please read the instructions relating to trouble-shooting
thoroughly.
Instructions for mounting the 4 locking plates on the cover
For pools with steps we recommend fitting locking plates to the cov-
er. These locking plates stop the cleaner from tipping.
Attach the stabiliser as shown in the photo. Fig. 22
Screw the screw in through the hole in the cover and tighten. Fig. 23.
Tighten the stabiliser with a Philips screwdriver.
Trouble shooting
Fault
Cause
The power ca-
Cable was not re-
ble is twisted
leased properly
or tangled
The cable in the wa-
ter is too long.
Cleaner is stuck on
the outlet grille
The
cleaner
The power unit is in
cannot
reach
the wrong place
all areas.
Water circulation in
the pool is switched
on.
Connection cable is
too short
Cleaner
does
Filter bag is blocked
not climb up
the pool wall
Algae is growing on
the walls
Water temperature is
too high / too low
Brushes are worn
The cleaner is too
light, it is tilting
PH value is not cor-
rect
Cleaner is not
Power pack is not ful-
operating
ly plugged in
The
cleaner
Page 8 of 56
Solution
Switch off the unit, re-
lease and uncoil the ca-
ble.
Remove the excess ca-
ble from the water.
Switch off the filter unit.
Position the power unit
so that the cleaner can
reach all areas properly.
Switch off the filter unit.
Place the greatest possi-
ble length of connecting
cable into the pool, but
bear in mind the corre-
sponding minimum dis-
tance between the oper-
ating unit and the pool
Replace the filter bag
Clean the pool walls
Optimal water tempera-
ture is between 10°C and
32°C
Contact a dealer, replace
the brushes
Switch the unit off and al-
low the air to escape
Test the value to keep it
between 7.0 and 7.4
Check the power cable
and the operating unit.
was
Contact a specialist re-
damaged
transport.
The
operating
needs
a
voltage to the local
one.
Cleaner
does
There is air in the
not sink
cleaner
Drive
roller
Foreign body in the
breaks off
drive
Cleaner comes
Cleaner climbs too
up
high, air in the clean-
er
Cleaner
is
Faulty operation
faulty
Guarantee
A guarantee will only be undertaken by the manufacturer with regard
to safety and reliability under the following circumstances:
Ø The floor vacuum cleaner is used in accordance with the guid-
ance in the instruction manual.
Ø Only original replacement parts were used in any repairs (Parts
liable to wear and tear are not covered by guarantee).
Consequential damages
We cannot be held liable for damage to the product which is caused
by not following the directions in this manual.
WEEE EU-Regulations
Please consider the regulations in the European Union and help pro-
tect the environment. Bring any faulty electrical parts to a recycling
centre in your town, which recycles electrical equipment in accord-
ance with regulations. Do not dispose of equipment in unsorted
waste bins.
Service
Please do not send the equipment to us without authorisation, but
please contact our service centre initially!
If the equipment has to be collected, it must be packed securely and
the invoice (copy) must the enclosed.
As soon as the unit reaches us, it will be checked for faults by our
claims department, and repaired. On conclusion of this work, your
equipment will be returned to you as quickly as possible.
If this return is not covered by the guarantee, the costs incurred will
be calculated.
Guarantee processing / guarantees are handled by the company
Steinbach VertriebsgmbH.
The item will be repaired by the company Steinbach VertriebsgmbH,
however where no right of return exists it will not be taken back.
Steinbach VertriebsgmbH,
Aistingerstrasse 2, 4311 Schwertberg, Austria
e-mail: service@steinbach.at
www.steinbach.at
during
tailer
unit
Contact a specialist re-
different
tailer
Switch the unit off, allow
the air to escape, and let
the cleaner sink to the
bottom.
Contact a specialist re-
tailer
Switch the unit off, allow
the air to escape.
Contact your retailer