3. Remove the plug on the underside of the housing
and connect the water drainage to the underside
of the housing (C) with the hose.
4. Please ensure that this condensation water can
always drain away and the hose is firmly
attached.
5. Remove the condensate collector.
6. For operation with the condensate collector,
close off the water drainage with the plug (D)
which was previously removed from the
underside of the appliance.
7. Insert the condensate collector back into the
appliance.
Please note: If the water is very cold you will
have to take appropriate measures to prevent
the water from freezing in the drainage hose.
It is recommended that the condensate be
drained off to a drain which is at a lower level. If
you use an external collecting container (e.g. a
trough), the appliance must be positioned at a
higher level accordingly.
The drainage hose must be fitted with a gradient.
Do not kink the hose or allow it to become
clogged.
7. Cleaning, maintenance and ordering
of spare parts
Always pull out the mains power plug before starting
any cleaning work.
Cleaning the air filter
The equipment is fitted with a dust filter. This should
be cleaned at least once a month dependant on the
operating conditions.
Important: Never use the equipment without air
filters.
Pull on the lug and remove the dust filter. Use a
vacuum cleaner or tap the dust filter gently to remove
the dust. If the filter is very dirty, wash it carefully with
warm water (max. 40°C). Never expose the filter to
the sun or any other sources of heat. Never fit the
filter back in the equipment while still damp.
Cleaning
Clean the equipment regularly with a moist cloth
and some soft soap. Do not use cleaning agents or
solvents; these could attack the plastic parts of the
equipment. Ensure that no water can seep into the
device.
12
19.01.2011
8:46 Uhr
Seite 12
Storage
If you do not intend to use the dehumidifier for a long
period, do the following:
Switch off the unit, pull out the power plug and
reel up the power cable.
Empty the water tank and carefully dry it.
Clean the ventilation grille, place a cover over
the unit and store it where there is little sunlight.
Maintenance
There are no parts inside the equipment which
require additional maintenance.
Ordering replacement parts:
Please quote the following data when ordering
replacement parts:
Type of machine
Article number of the machine
Identification number of the machine
Replacement part number of the part required
For our latest prices and information please go to
www.isc-gmbh.info

8. Disposal and recycling

The unit is supplied in packaging to prevent its being
damaged in transit. This packaging is raw material
and can therefore be reused or can be returned to
the raw material system.
The unit and its accessories are made of various
types of material, such as metal and plastic.
Defective components must be disposed of as
special waste. Ask your dealer or your local council.
9. Troubleshooting
The unit fails to start:
- Check whether the power plug is correctly
inserted.
- Check whether there is any electricity.
- Is there a power failure?
- Is the lamp on the water level indictor shining?
If it is, either the tank is full and must first be
emptied or the tank is not correctly inserted.
The unit seems to be having no effect:
- Is the filter dirty or contaminated?
- Is the air inlet or outlet blocked?
- Is the humidity in the room already very low?