Connecting-up
X2 – Motor
The motor connection is to a terminal block at the bottom of the unit.
connection ≥ 22 kW
U2
V2 W2
Connectable cross-section:
Maximum cross-section: 50 mm² (AWG 1/0),
Minimum cross-section: 10 mm² (AWG 6)
PE terminal is at the bottom right of the shield plate.
Table 7-5
The motor cables must be dimensioned in accordance with VDE 298,
Part 2.
After installation of the connector, the shield of the motor cable must be
fixed to the shield plate through a large surface area.
7-8
Terminal
Protective conductor connection
U2 / T1
Phase U2 / T1
V2 / T2
Phase V2 / T2
W2 / T3
Phase W2 / T3
Motor connection
Operating Instructions
Meaning
3AC 0 V - 480 V
3AC 0 V - 480 V
3AC 0 V - 480 V
6SE7087-6KP50
SIMOVERT MASTERDRIVES
06.2006
Range