Herunterladen Inhalt Inhalt Diese Seite drucken

Smeg KSEV 910 X1 Montageanweisung Und Gebrauchsanweisung Seite 22

Dunstabzugshaube
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Functioning - 6-key electronic model
1
2
3
1- Motor OFF key.
2- Diminishes the speed.
3- Increases the speed.
4- 5/15 minutes timer. Inserts and extracts the timer.
The speed in function is turned off automatically.
5- Resets carbon filters saturation indicator.
When the F led lights up, the carbon filter should be
cleaned or changed.
Press for at least 3 seconds after having changed the
carbon filter. The F led will turn off to indicate the resetting
of the saturation indicator.
Note: This led switches ON even if the carbon filter has
not been mounted.
6- ON/OFF light.
If the hood fails to operate correctly, briefly disconnect it from
the mains power supply for almost 5 sec. by pulling out the
plug. Then plug it in again and try once more before
contacting the Technical Assistance Service.
Electronic model with sensor
1
2
3
S
F
C
T1
T2
1
2 3 4
T1. Hood On/Off key
T2. Increase cyclical motor speed key.
Pressing the first time activates speed 1. A Led (1-2-3),
corresponding to each speed, switches on. Led 4 flashes
at intensive speed.
After 5 minutes intensive speed is reduced to the second
speed. If key T2 is pressed before the end of the 5
minutes, the hood retunes to the first speed.
T5. Lights On/Off key.
Filter signals
(function active with the hood on): the fats filter signal
appears after 80 hours functioning (Led 1 flashing).
The carbon filter signal appears after 320 hours (Led 2
flashing). In the case of simultaneous signalling of the fats
and carbon filters, Leds 1 and 2 flash alternatively.
Reset filter signals:
press key T4 for 3 seconds until Led 1 switches off (fats
filter). In the case of both filters (fats and carbon)
signalling, repeat the operation just described: pressing T4
the first time switches off Leds 1 and 2 that are flashing
alternatively. Immediately afterwards Led 2 flashes again:
at this point press T4 again for 3 seconds. A beep signals
each time the operation is completed.
Enabling the carbon filter signal:
the hood is enabled only for the fats filter signal. To enable
4
5 F
6
Sensor
Reset
T3
T4
the carbon filter signal: hood in Off, press keys T2 and T4
for 3 seconds. The flashing of Leds 1 and 2 signals the
completion of the setting. To disenable the carbon filter
signal, repeat this operation again (always with the hood
in Off). A beep signals each time the operation is
completed.
Automatic calibration:
the system carries calibration out automatically about
every 30 minutes (calibration of the parameters
functioning of the sensors).
Manual calibration:
with the hood in Off, press keys T3 and T4 until the beep.
Automatic functioning:
to activate automatic functioning, press key T3: Led 4
switches on. To return to manual functioning, press key
T1, T2 or T3.
Sensors test:
this happens continuously during automatic functioning. In
the case of damage all the Leds flash: in this case, return
to manual functioning, pressing keys T1, T2 or T3.
Selecting cooking top:
this operation optimises the automatic functioning of the
hood: with the hood in Off press keys T2 and T3 for about
0/I
3 seconds until the cooking top at present in use is seen:
gas top - Led 1 on
induction top - Led 2 on
T5
electric top - Led 3 on.
Select the cooking top requested pressing T2, then press
T2 and T3 simultaneously for three seconds until the
Beep. Alt the end the hood switches off.
The gas top is the default state.
Attention: carry out this operation the first time the hood
is switched on.
22

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Li2kklCh siena e 60inx

Inhaltsverzeichnis