based in Hirschau and to municipal disposers (valuable materials
yards) which are obliged to accept them.
Do make your contribution to environmental protection.
Alternating-current measurement ACA
- Turn the functional rotary switch to "A~"
- Open the current clip by pressing the opening handle and place
the current clip around the individual line to be measured (see
the figure). Placing it around several lines at the same time results
in an erroneous measurement.
- Close the clip and read out the value measured.
Important:
Remove the measuring lines from the tester before making this
measurement.
Right
22
Wrong
Direct-current measurement DCA
- Turn the functional rotary switch to "A = "
- Press the zero key to set the measured-value read-out to zero.
- Open the current clip by pressing the opening handle and place
the current clip around the individual line to be measured (see
the figure). Placing it around several lines at the same time results
in an erroneous measurement.
- Close the clip and read out the value measured.
Note:
Remove the measuring lines from the tester before making this
measurement.
23