12.1 Technical problems

Problem/alarm code
You cannot activate the ap-
pliance.
The programme does not
start or stops during opera-
tion.
The appliance stops and
starts more times during
operation.
The programme lasts too
long.
The remaining time in the
display increases and skips
nearly to the end of pro-
gramme time.
The appliance door is diffi-
cult to close.
Rattling/knocking sounds
from inside the appliance.
The appliance trips the cir-
cuit-beaker.
Possible solution
• Make sure that the mains plug is connected to the
mains socket.
• Make sure that there is no damaged fuse in the fuse
box.
• Make sure that the appliance door is closed.
• If the delay start is set, cancel the delay setting or wait
for the end of the countdown.
• The appliance has started the procedure to recharge
the resin inside the water softener. The duration of the
procedure is approximately 5 minutes.
• It is normal that the appliance stops and starts during
the programme in order to provide optimal cleaning re-
sults and energy savings.
• In models with the ''water sensor'' you will hear more
stops and starts during the programme. This depends
on the selected programme and the level of soil
sensed.
• An energy-saving programme has been selected, in
this case the total programme time increases to com-
pensate the lower washing and drying temperatures.
Use these programmes preferably at night.
• If the delay start is set, cancel the delay setting or wait
for the end of the countdown.
• This is not a defect. The appliance is working correctly.
• Parts of the tableware are protruding from the baskets
(e.g. pot or pan handles, ladles).
• The tableware is not properly arranged in the baskets,
items are touching each other.
• One or both spray arms are touching the tableware
while turning. Make sure that the spray arms can ro-
tate freely otherwise the cleaning results will be heavily
affected.
• The amperage is insufficient to supply simultaneously
all the appliances in use. Check the socket amperage
and the capacity of the meter or turn off one of the ap-
pliances in use.
• Internal electrical fault of the appliance. Contact an Au-
thorised Service Centre.