3
Conditions at the site of installation
3.1
Ambient pressure
The ambient pressure for transducers may be between 0 and 5 bar. Please
note that pressure changes may shift the zero output signal.
Max. capacity
Change of zero
point [%/10 mbar]
3.2
Special information
The C2 transducers are produced entirely from non-rusting materials. The user
must test for resistance to aggressive environmental conditions in each individ
ual case.
C2
kg
50
100
t
0.065 0.032 0.016 0.006 0.003 0.006 0.003 0.002 0.001 <0.001
A1683-2.0 HBM: public
Conditions at the site of installation
200
500
1
2
5
10
20
50
7