3. Electrical connection
To comply with the required maximum ratings (see table above) in accordance with EN
61000-3-11 the required power impedances are to be notified to the local power supply
company!)!
Attention: always observe local ordinances!
Gas appliances:
Model
Unit size
Connection power 400V
Rated current 400V
Rated Connection
[mm²]
average *
Connection power 230V
Rated current 230V
Rated Connection
[mm²]
average *
Model
Unit size
Connection power 400V
Rated current 400V
Rated Connection
[mm²]
average *
Connection power 230V
Rated current 230V
Rated Connection
[mm²]
average *
* Recommended connecting line laid open to the air for max. 5 m long!
Attention: always observe local ordinances!
6.10
6.20
3/N/PE ~ 400 V 50/60Hz
[kW]
1.1
1.1
[A]
2.9
2.9
5 x 1.5
5 x 1.5
1/N/PE ~ 220V - 240 V 50/60Hz
[kW]
1.4
1.4
[A]
4.9
4.9
3 x 1.5
3 x 1.5
6.10
6.20
3/N/PE ~ 400 V 50/60Hz
[kW]
1.0
1.0
[A]
2.5
2.5
5 x 1.5
5 x 1.5
1/N/PE ~ 220V - 240 V 50/60Hz
[kW]
1.3
1.3
[A]
4.5
4.5
3 x 1.5
3 x 1.5
41
OGB
10.10
10.20
12.20
1.1
1.5
1.5
2.9
3.5
3.5
5 x 1.5
5 x 1.5
5 x 1.5
1.4
1.8
1.8
4.9
6.1
6.1
3 x 1.5
3 x 1.5
3 x 1.5
OGS
10.10
10.20
12.20
1.0
1.4
1.4
2.5
3.1
3.1
5 x 1.5
5 x 1.5
5 x 1.5
1.3
1.7
1.7
5.0
5.7
5.7
3 x 1.5
3 x 1.5
3 x 1.5
EN
20.10
20.20
2.15
2.2
5.0
5.4
5 x 1.5
5 x 1.5
2.6
2.7
9.0
9.4
3 x 1.5
3 x 1.5
20.10
20.20
2.0
2.1
4.6
5.0
5 x 1.5
5 x 1.5
2.5
2.6
8.6
9.0
3 x 1.5
3 x 1.5