Setting the box ID of the connection box
Connecting the connection box
X10
Contact
Assignment
③
1
Functional
grounding
2
3
4
Not connected
5
STOP 13
6
STOP 14
7
STOP 23
8
STOP 24
9
ENABLE2+
10
ENABLE1–
11
ENABLE1+
12
ENABLE2–
Siemens AG
Division Digital Factory
Postfach 48 48
90026 NÜRNBERG
GERMANY
Connection box standard and connection box advanced
A5E33878459-AB, 12/2015
4
Circuits
Grounding and
24 V DC power supply
Observe notes in the
M
operating instructions.
P24
Emergency stop / stop
button
Only for a hardwired
F-system
Enabling button
Only for a hardwired
F-system
Set an individual box ID for each connection box.
Requirement
The connection box is open.
•
A suitable tool made of plastic
•
Procedure
Rotate the arrows of the rotary coding switch to the required
hexadecimal value using a suitable tool.
Values from "00" to "FF" (0 to 255 in decimal form) can be set
with the rotary coding switches.
When setting the box ID:
Use the value "00" only for the "Stop button evaluated by
•
safety relay" operating mode.
The value "FF" (255) is reserved and may not be used.
•
In the example on the left, the box ID is set to "27H"
(39 in decimal format).
①
②
/
Fast connectors X1 and X2
③
Plug-in terminal strip X10
X1/X2
Contact
Color
①
1
Yellow
②
2
White
3
Orange
4
Only if the PLC is connected directly to the
1
connection box.
Connection box standard and connection box advanced
Assignment
connection box
RD+
TD+
RD–
Blue
TD–
A5E33878459-AB, 12/2015
Assignment
PLC
1
TD+
RD+
TD–
RD–