Siemens 6AV2125-2AE13-0AX0 Produktinformation Seite 4

Anschluss-box standard und anschluss-box advanced für siemens simatic hmi mobile panels 2nd generation

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Setting the box ID of the connection box
Connecting the connection box
X10
Contact
Assignment
1
Functional
grounding
2
3
4
Not connected
5
STOP 13
6
STOP 14
7
STOP 23
8
STOP 24
9
ENABLE2+
10
ENABLE1–
11
ENABLE1+
12
ENABLE2–
Siemens AG
Division Digital Factory
Postfach 48 48
90026 NÜRNBERG
GERMANY
Connection box standard and connection box advanced
A5E33878459-AB, 12/2015
4
Circuits
Grounding and
24 V DC power supply
Observe notes in the
M
operating instructions.
P24
Emergency stop / stop
button
Only for a hardwired
F-system
Enabling button
Only for a hardwired
F-system
Set an individual box ID for each connection box.
Requirement
The connection box is open.
A suitable tool made of plastic
Procedure
Rotate the arrows of the rotary coding switch to the required
hexadecimal value using a suitable tool.
Values from "00" to "FF" (0 to 255 in decimal form) can be set
with the rotary coding switches.
When setting the box ID:
Use the value "00" only for the "Stop button evaluated by
safety relay" operating mode.
The value "FF" (255) is reserved and may not be used.
In the example on the left, the box ID is set to "27H"
(39 in decimal format).
/
Fast connectors X1 and X2
Plug-in terminal strip X10
X1/X2
Contact
Color
1
Yellow
2
White
3
Orange
4
Only if the PLC is connected directly to the
1
connection box.
Connection box standard and connection box advanced
Assignment
connection box
RD+
TD+
RD–
Blue
TD–
A5E33878459-AB, 12/2015
Assignment
PLC
1
TD+
RD+
TD–
RD–