TECHNICAL SUPPLEMENT
CARE
AND MAINTENANCE OFTHE
REVOX PR99
The maintenance
work
is reduced
to
cleaning and demagne-
tizing the tape guidance
elements.
Note:
During the cleaning, take care
that
no
cleaner
comes
into
the bearing of the capstan
axle.
The
tape guides should
be
cleaned prior to each recording
be-
cause
contaminants
can
cause
recording
gaps
or
so-called
d
rop
outs.
For
optimum
cleaning
use
the
Revox
cleaning set (order code
39000). lt
contains all utensils necessary
for
cleaning the ma-
chine and
a
special cleaning fluid.
Lubrification
of the
sintered bearing
bushes
and of
the
ball
bearing
is
described
in
the service instructions.
Procedure
Dip
a
felt
swab
into the cleaning
fluid
and clean
alltape guidance
elements. Dry the cleaned surfaces
with
a
new
dry
felt
swab.
Demagnetizing
After
approx. every 100
hours
of
operation
(or prior
to
a
record-
ing).
demagnetize the
soundheads
and
tape
guidance
elements.
Use a
demagnetizer (order
no.
10.042002.01)
Procedure
(Tape
deck
switched
off.
no
tape
on
the spindles).
Slowly
bring
the
tip
of the
demagnetizer
in
close proximity
to the
component
to
be
demagnetized.
After a
few
seconds,
retract
the
choke
slowly. This
procedure should
be repeated
for
alltape
guidance
elements
and
heads
shown in the corresponding
illustration.
The demagnetizer can be
switched of
in
a
distance of
approx.
50
cm
(20")
CALIBRATION
AND
RECALIBRATION
OF
THE REVOX PR99
General
The
adjustments
based
on
NAB or
CCIR
test tapes are
different
in
the
following
details:
NAB:
Operational
level
approx.
6
dB
below peak
recording
level.
The intensity
of magnetization
is
250 nWb/m
and
500
nWb/m
at
peak
recording
level.
The
machine
is
fac-
tory-adlusted to these
values.
CCIR:
Reference level
+peak
recording
level.
Magnetizing
force is (factory
adjusted) 51OnWb/m.
To
simplify
the instructions, the reference
is
the
operating
le-
vel
(o0VU
resp.
6
dB
below
peak recording
level).
Calibration of
input circuit:
1.
Remove machine
from
housing (case) (undo
4 screws
on
back of
unit).
2.
ConnectAF
millivoltmeterto
monitor connector
pin 3
(CH1)
/
pin 5
(CH2)
and pin 2
(GND).
3.
With
AF
generator, apply
1
kHz
signal
of
desired
operating
le-
vel for
0VU.
4.
Switch
on machine.
5.
Release
UNCAL button
[21]
and SYNC button
[31]
6.
Set
OUTPUT
switch [20]
to the INPUT/
SYNC
position.
7.
Adjust monitor output
Io
0.775V
with
potentiometer
RB
(CH1)
or
R16
(CH2)
respectively
(PCB LINE INPUT CIRCUIT)
B
The sensitivity can be increased
for
small levels
by
replug-
ging
lumpers
S
1/S2.
located
behind
potentiometers
RB/Rl6,
to
position
A or
B
(sequence
viewed from
potentiometers:
CBA)
9.
Switch
machine off and reinstall
in housing.
ORIGI
NAL
REVOX ACCESSORIES
PR99 MIC
INPUT BALANCED
(Retrofit
kit)
Remote
control
unit,
incl.
10
m cable
Capstan motor.control
-F7
semitones
Tool
set
PR99
NAB
adapter
(black)
NAB
adapter (professional)
AEG
flange
for
single sided
spool
(horizontal operation
only)
Cleaning
set
Demagnetizing
choke
Revox
microphone
M3500
Revox
headphones
RH310
14
Order
code:
1
.177.885
34227
?L)2-7
20.020.00110
45001
4501 0
34501
39000
10.042.002.01
30450
3201 0