Herunterladen Inhalt Inhalt Diese Seite drucken

STUDER REVOX PR99 Bedienungsanleitung Seite 38

Tonbandmaschine
Vorschau ausblenden Andere Handbücher für PR99:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Note: The
clock track should
be heard by the
vocalist-instru-
mentalist via
headphone.
When monitoring
with
speakers,
por-
tions
of
the
clocktrackwillalso
be
included
in
the
microphone
in-
put
The
recording can
be checked
by switching
to normal
repro-
duce mode
(OUTPUT
switch [20] to
REPRODUCE).
Depending
on
the setting of the
output
mode
selector,
the
fol-
lowing
can
be
checked:
MONO
both channels
mixed
CHl/CH2
only the
track
selected
STEREO
on one side. the
clock track
will
be heared and on
the other
side,
the synchronous recording
lf
the recordlng
is
satisfactory,
it
can
be
copied to
a
second tape
deck (mixed) after
which
a
new
track
can
be
recorded.
Note: Synch-reproduction
is
possible only on one
or
the other
channel.
lf
both channels
are
selected, the tape deck operates
in
non-synch mode
in
which
case
reproduction occurs via repro-
duce
head.
ECHO
ARRANGEMENTS
With
separate
recording
and
reproducing
heads.
it
is
possible
to
generate echo effects
without
auxiliary equipment.
During recording,
the input signal
is
available
at
the
reproducing
head
with
a
defined time
delay.
lf
the signal
is
fed
back to
the
re-
cording
head
f
rom the
reproducing
head,
itwill
be
recorded
a
se-
cond
time with
a
corresponding
delay. The
first
echo
is
again
fed
backfrom
the reproducing
head, and thus,
with
the same delay.
generates
a
second echo,
etc.
The
time intervals between echoes
is
directly dependent
on
the
tape speed. At
38.1
cm/sec.
it
measures
0.085
sec.,
at19 05
cm/
sec.
it
is equal
to
0.17sec. and
at 9.5cm/sec. it
is equal
to
0.34 sec.
Echo
arrangements
for recording operations
connect
source
to
N/lc
/
LINE INPUT
CH1.
Set input selector
[29]
CH1
to the desired
source.
Set recording preselector [25] to the
READY
position.
set
input selector
[29] cH2 to
GH1-CH2.
Start tape deck in recording
mode.
Depress
UNCAL button [30], allowing
the
volume
of
the echo
to
be
adjusted
with
INPUT
LEVEL
control
l2gl
CH2
Echo
arrangements for
existing recordings
ln
orderto
mix
an
echo
with
an
existing recording,
the
sound
ma-
terial must
first
be
copied to the other track.
Set recording preselector
[25]
of
the
recorded channel
to
the
SAFE
position.
the selector
of
the
unrecorded channel
to
the
READY
position,
Set input selector
l29l
of
the unrecorded
channel
to
CHI-CH2
or CH2-CH1
as required.
Set input selector
of the
recorded channel
to
CH2-CH1
or
CHI-CH2
as required.
Start tape
deck
in
recording
mode.
Depress UNCAL
button [30], allowing the
echo content
to
be
regulated
with
INPUT
LEVEL
control [28]
of
the recorded chan-
neland
the
copy levelto
be
regulated
with
the
INPUT LEVEL
con-
trol [28]
of
the unrecorded
channel.
Note:
The recording can be repeated at
any
time
because
the
original track
will
not
be erased.

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für STUDER REVOX PR99

Inhaltsverzeichnis