Overflow valve
– If the hand spray gun is closed, the
overflow valve opens and the high pres-
sure pump diverts the water back to the
pump suction side. Thus the permissi-
ble working pressure is not exceeded.
– The overflow valve is set by the manu-
facturer and sealed. Setting only by
customer service.
Safety thermostat at the pump
The safety thermostat switches off the mo-
tor when the maximum permissible temper-
ature has been exceeded.
DANGER
Risk of injury! Device, tubes, high pressure
hose and connections must be in faultless
condition. If they are not in a perfect state
then the appliance must not be used.
Check oil level of the high pressure
Check oil level in the oil tank.
The oil level must lie between "MIN"
and "MAX" marking.
Add oil if required (see technical speci-
fications).
Follow the instructions given in the sec-
tion "Safety Instructions"!
Read the operating instructions of the
engine manufacturer before start-up
and follow the safety instructions care-
fully.
Fill the fuel tank with unleaded petrol.
Do not use 2-speed mixture.
Check oil level of the engine.
Do not operate the appliance if the oil level
has fallen below "MIN".
If required, top up oil carefully.
14
Start up
pump
Motor
Attaching the Accessories
Mount the nozzle on the spray lance
(markings on the adjustment ring at the
top).
Connect spray lance to trigger gun.
Lever out the safety clip of the hand spray
gun using a screw-driver (Picture A).
Place the hand-spray gun upside down
and insert the end of the high pressure
hose till the end. Ensure that the lose
disc falls right below on the hose end
(Picture B).
Press the safety clip back into the hand-
spray gun. The hose can be pulled out
max. 1 mm if it has been installed cor-
rectly. Otherwise, it means the disc has
been installed wrongly (picture C).
Connect the high pressure hose to the
high pressure connection point of the
machine.
Water connection
– For connection values refer to technical
specifications
WARNING
Observe regulations of water supplier.
According to applicable regula-
tions, the appliance must never be
used on the drinking water net
without a system separator. A suit-
able system separator by KÄRCHER or al-
ternatively a system separator according to
EN 12729 type BA must be used.
Water that was flowing through a system
separator is considered non-drinkable.
CAUTION
Always connect the system separator to
the water supply, never directly to the appli-
ance!
Connect the supply hose to the water
connection point of the machine and at
the water supply point (for e.g. a tap).
Open the water supply.
Note:
The supply hose is not included.
– 3