If a Firewall (e.g. Windows Firewall) is active on the PC, the following ports must be
cleared as an exception:
4500 (TCP);
For DoIP (not supported by I+ME ACTIA software in the Daimler AG environment;
additional software is required):
13400 (UDP & TCP);
If another IP address and another IP address subnet are to be used to communicate
with the eCOM Box (e.g. in a larger network infrastructure), configuration settings with
the TKAdministration-Tool are required. Observe that each configuration requires a
functional Unicast communication between PC and eCOM Box (i.e. both devices in the
same IP subnet). The following figure shows the dialogue in the TKAdministration-Tool,
which permits setting of the eCOM Box network interface.
If a static IP address is selected manually, ensure that it is not assigned multiply.
4349 (TCP);
4009 (UDP);
13401 (UDP & TCP);
Figure 3: TKAdministration – IP adress configuration
4011 (UDP)
13402 (UDP & TCP);
Page 25
6. Software
13403 (UDP & TCP);