83100811.qxd
11.09.01

Motor run time

The motor run time is set to 120 seconds by the manufacturer. With
the program option "set motor run time" you can set the motor run
time variably from 3 seconds to 120 seconds.
Press set and programming button (P) simultaneously. Then repeat
pressing only the set button until the display indicates the following:
(=ß1ß2ß0)
This is the menu option "motor run time".
By pressing the up button you can set the time in seconds at which
the roller shutter shall move down.
After approx. 2 minutes the display switches to the current time and
the roller shutter control switches to the programmed up and down
times.
12:17
Seite 63
Programming the special functions
- 61 -
Programming the special functions
After the roller shutter has moved down at the programmed time, the
reverse function causes it to shortly move up for airing purposes or to
let pets go outside.
The reverse time can be variably set between 0.0 and 20 seconds
and will be executed in the automatic operation at the programmed
times of the day, week and sunrise/sunset.
Important: The reverse function will only be activated after the down
pulse is released.
Press set and programming button (P) simultaneously. Then repeat
pressing only the set button until the display indicates the following:
display:
This is the menu option "reverse function".
Press the up button to set the time in seconds at which the roller
shutter shall move up again after the down command.
After approx. 2 minutes the display switches to the current time and the
roller shutter control switches to the programmed up and down times.
G
G

Reverse function

K
K
(0ß0:0ßßr
sec.
!ß10 sec.
- 62 -