Installation

• There are specifi c regulations like BGV C1 (old VBG 70) or country related regulations which need to attend during the
installation. The installation has to be handled by skilled persons only!
• Suspension device hast to be built and calculated in order to handle up to 10 times its specifi c load limit over a time of
one hour without permanent or harmful deformation.
• Installation has to be done with a separate, independent suspension device like a safety chain. A second suspension
device has to be built in order to assure that in case of error no part of an installation can fall off.
• Trepassing the danger zone below the installation during the assembling is prohibited.
• Installer has to take care of all safety and machinery installations are approved by authorized persons before fi rst opera-
tion or after changes before restarting.
• Installer has to take care of all safety and machinery installations are approved by skilled persons at least once a year.
• Installer has to take care of all safety and machinery installations are approved by authorized persons at least every four
years during the acceptance inspection.
• Spotlight should ideally installed outside peoples lounge area.
ATTENTION!
Installation overhead needs a high level of experience. This includes (but is not just limited to) calculation and defi nition
of load capacity, used installation material and regular safety inspections of used material and the fi xture itself. Never
try to do the installation by yourself if you are not qualifi ed, instead you have to instruct a skilled installer. Inappropriate
installations can cause injuries and/or damage of property.
• Spotlight has to be installed outside areas where people can touch it.
• Professional truss system or similar licensed suspension systems have to be used if the spotlight is used in suspension
from ceiling or other constructions. Spotlights can never be installed freely suspended!
ATTENTION!
Spotlights can cause injuries when fall off. If you are not trained in questions of safety for the different kinds of
installation do NOT install the spotlight!
• Assure that the mounting surface can hold at least ten times the point load of the spotlight before installing the fi xture.
ATTENTION!
Assure the specifi ed safety distances to fl ammable material.
• Attach the spotlight with its yoke and the use of a suitable hook/clamp to your truss system. According to your installa-
tion also similar but approved suspension devices are possible. The therefor used opening has a diameter of about 12
mm.
• When installing the spotlight overhead make sure to safe the fi xture by a safety chain which is specifi ed at least with a
load limit of 12 times of the spotlights weight. Only safety chain with approved connective can be used. Attach the safety
chain to its designated opening and attach it to the truss system or a similar and safe attachment point. Assure to close
the fasteners as specifi ed.
• To adjust the angle of the fi xture open the locking screw, set the fi xure in its position and close it by hand.