6. Notes for mounting and operating in hazardous areas
6.3.2 Sensor (terminal 1 to 3)
The connected sensor must not warm up inadmissably according to
the temperature class of the respective hazardous area for the
following values for voltage, current and power:
Model T24.10.**2
II 1G EEx ia
Model T24.10.**9
II 3G EEx nL/nA
The sum of the values of the connected sensor and the connection
line must not exceed the following values for the maximum
permissible capacitance and inductance:
Mod. T24.10.**2 II 1G EEx ia Group IIB
Mod. T24.10.**2 II 1G EEx ia Group IIC
Mod. T24.10.**9 II 3G EEx nL/nA
WIKA Operating instructions temperature transmitter Model T24.10
maximum possible values
U
= DC 6.4 V
0
I
= 42.6 mA
0
P
= 37.1 mW
0
effective values during operation
U
= DC 5.4 V
0
I
= 0.5 mA
0
C
+ C
< C
sensor
line
O
L
+ L
< L
sensor
line
O
C
+ C
< C
sensor
line
O
L
+ L
< L
sensor
line
O
C
+ C
< C
sensor
line
O
Group IIC
L
+ L
< L
sensor
line
O
GB
C
= 500 µ F
O
L
= 50 mH
O
C
= 20 µ F
O
L
= 10 mH
O
C
= 200 µ F
O
L
= 1000 mH
O