5. DC Current Measurement
a)
Connect red test lead to "Current (10 A) Terminal" (3-19, Fig. 1) and black
test lead to "COM Terminal" (3-18, Fig. 1).
b)
Open the circuit in which current is to be measured. Now securely connect
test leads in series with the load, which the current is measured.
c)
The display will show the DC current directly.
* The max. DC current input value should be less than 10 A.
7.6. Ohm Measurement
1. Push the "Power Switch" (3-2, Fig. 1) to "On" position.
ON = 1
OFF = 0
2. Select the "Ohm Switch" (3-5, Fig. 1)
3. Connect red test lead to "V/Ohm Terminal" (3-17, Fig. 1) and black test lead to
"COM Terminal" (3-18, Fig. 1)
4. If the resistance being measured is connected to a circuit, turn off power to circuit
being tested and discharge all capacitors.
5. Connect test lead probes into circuit (resistance) under test.
6. Read resistance value on digital display.
7.7. AC Watt, VA, Whr measurement, current input cooperate with CT (Current
Transformer)
Other measurement procedures are same as the 7.1, 7-2, except:
1. Wire connection as follows, refer (Fig. 3)
Voltage:
"V-Terminal" (3-17, Fig. 3) and "COM Terminal"
(3-18, Fig. 3)
Current:
Current transformer output connect to the "10 A Terminal"
(3-19, Fig. 3) and "COM terminal" (3-18, Fig. 3)