* Accuracy is specified under the following conditions:
a)
AC input current is ≥ 0,05 A AC & ≤ 10 A AC
b)
AC input voltage is within 110 V ± 15% and 220 V ± 15% (50/60 Hz)
* ACA, ACV frequency response is from 40 to 400 Hz
4.2.4. Power Factor, current mode from direct input only
Range
0,01 to 1,00
* Accuracy is specified under the following conditions:
a)
AC input current is ≥ 0,05 A AC & ≤ 10 A AC
b)
AC input voltage is within 110 V ± 15% and 220 V ± 15% (50/60 Hz)
* Max. volt & current input signal value:
Volt input: Max. AC 600 V, Current input: Max. AC 10 A
4.2.5. AC Voltage (true rms), DC Voltage
Range
Resolution
0,1 V to 299,9 V
0,1 V
300 V to 600 V
1
* Auto range
* Max. input voltage: 600 V AC/DC
* ACV accuracy is test under input signal is sine wave, 50/60 Hz
* ACV frequency response is from 40 to 400 Hz
* ACV is true rms.
4.2.6. AC Current (true rms), DC Current; current mode from direct input
Range
0,05 A to 1,999 A
ACA
2,00 A to 10,00 A 10 mA
DCA
0,01 A to 10,00 A 10 mA
Resolution
0,01
Accuracy
DCV
ACV (≤ 10 V) : ± 1% + 7 dgt.
V
(11 V to 100 V): ± 1% + 5 dgt.
(>100 V)
Resolution
1 mA
-26-
Accuracy
± 1,5% + 2 dgt.
: ± 1% + 1 dgt.
: ± 1% + 1 dgt.
Accuracy
± 1% + 3 dgt.
± 1% + 1 dgt.