Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Specifications; Installation Positioning / Electrical Connection - Küppersbusch IKEF 238-6 Gebrauchsanleitung

Vorschau ausblenden Andere Handbücher für IKEF 238-6:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Technical specifications

The technical data is indicated in the rating plate on the left side inside the appliance.
If there is a power failure when food is in the freezer, do not open the door of the freezer
compartment. The frozen food will not be affected if the power cut is of short duration (up to 12
hours) and the freezer compartment is full, otherwise, it is recommended that the food should be
used within a short time (a temperature increase of the frozen food shortens its safe storage
period).
Installation
Take utmost care when handling your
appliance so as not to cause any damages to
the cooling unit with consequent possible fluid
leakages.
¥ During normal operation, the condenser and
compressor at the back of the appliance heat up
considerably. Always ensure that there is adequate
ventilation as a failure to do this will result in
component failure and possible food loss. See
installation instructions.
¥ Important: if the supply cord is damaged, it must
be replaced by a special cord or assembly availa-
ble from the manufacturer or its service agent.
Positioning
¥ Unpack the cabinet and check that it is in good
condition and free of any transport damage.
¥ The appliance must not be located close to
radiators or gas cookers.
¥ Avoid prolonged exposure of the appliance to
direct sunlight.
¥ For safety reasons, minimum ventilation must be
as shown in Fig.
50 mm
D526
Attention: keep ventilation openings clear of
obstruction.
¥ It is necessary that the niche is provided with a
conduct of ventilation having the following
dimensions:
Depth 50 mm
Width 540 mm
The climate classification can be found on the rating
plate, which is located inside the cabinet on the left
hand wall.
The following table shows which ambient
temperature is correct for each climate classification:
Climate
classification
SN
N
ST
T
In order for the appliance to run properly in
certain conditions a slight heating of the back
surface of the inner container can take place.
Electrical connection
Before plugging in, ensure that the voltage and
frequency shown on the serial number plate
correspond to your domestic power supply.
Voltage can vary by ±6% of the rated voltage.
For operation with different voltages, a suitably sized
auto-transformer must be used.
min.
200 cm
2
for an ambient temperature of
Important
The appliance must be earthed.
The power supply cable plug is provided with a
contact for this purpose.
If the domestic power supply socket is not
earthed. connect the appliance to a separate
earth in compliance with current regulations,
consulting a specialist technician.
The
Manufacturer
responsibility
if
precautions are not observed.
+10 to +32¡C
+16 to +32¡C
+18 to +38¡C
+18 to +43¡C
declines
all
the
above
safety
23