3. If necessary, replace the defective door
gaskets. Contact the Service Center.

Technical data

Dimension of the recess
Rising Time
Voltage
Frequency
The technical information are situated in the
rating plate on the internal left side of the
appliance and in the energy label.

Installation

Read the "Safety Information" carefully
for your safety and correct operation of
the appliance before installing the
appliance.
Positioning
Install this appliance at a location where the
ambient temperature corresponds to the
climate class indicated on the rating plate of
the appliance:
Climate
Ambient temperature
class
SN
+10°C to + 32°C
N
+16°C to + 32°C
ST
+16°C to + 38°C
T
+16°C to + 43°C
Electrical connection
Before plugging in, ensure that the voltage
and frequency shown on the rating plate
correspond to your domestic power supply.
The appliance must be earthed. The power
supply cable plug is provided with a contact
for this purpose. If the domestic power sup-
ply socket is not earthed, connect the appli-
ance to a separate earth in compliance with
current regulations, consulting a qualified
electrician.
The manufacturer declines all responsibility
if the above safety precautions are not ob-
served.
Downloaded from Fridge-Manual.com Manuals
All manuals and user guides at all-guides.com
Height
Width
Depth
1780 mm
560 mm
550 mm
21 h
230-240 V
50 Hz
This appliance complies with the E.E.C. Di-
rectives.
Door reversibility
The door of the appliance opens to the
right. If you want to open the door to the
left, do these steps before you install the
appliance:
1. Loosen the upper pin and remove the
spacer.
2. Remove the upper pin and the upper
door.
3. Unscrew the pins (B) and spacers (C).
4. Remove the lower door.
5. Loosen the lower pin.