Commissioning

Please read the following instructions
carefully before using the device.
3
Commissioning
the plasma ONE treatment unit
3.1
Commissioning and explanation of the
energy control unit
3.2
Commissioning and explanation of the
converter
3.2
Commissioning and explanation of the
instrument probes
3.4
Commissioning and explanation of the
patient probe
3.1
Commissioning and explanation of the
energy control unit
Charge the energy con-
trol unit from the plug
socket before the first
use of the energy con-
trol unit or the complete
treatment unit. To do
this, plug the adapter
plug connector into the
energy control unit and then plug the mains plug into
the socket.
Socket for charging cable
The white LED display BATTERY – CHARGING illumi-
nates when the charging process is active! The white
LED display goes out when the battery is fully charged!
The green LED display POWER flashes if the charge
capacity of the battery is below 30%! A fully charged
battery enables at least 8 hours of active treatment.
You cannot perform treatment if the
energy control unit is still connected to
the mains. The treatment unit only op-
erates in battery mode.
Explanation of the display
The energy control unit is switched on with the
pushbutton.
The energy control unit is switched off with the
pushbutton.
Press the ON BUTTON until the POWER LED display
lights up green, or in case of OFF, until the POWER
LED display no longer illuminates.
The levels 1 to 5 of the LED display
indicate the in-
tensity of the plasma concentration.
The individual levels can be controlled with the
and
OFF
switches.
Click
ON
for a higher setting and
OFF
for a lower set-
ting.
1
Level
Level
2
Level
3
Level
4
5
Level
The recommended power
levels for the particular
indication is given in the list of recommended indica-
tions.
A list of indications can be found as an accessory in
the packaging.
The LED display
ACTIVITY
is a visual and acoustic in-
formation for the person performing treatment or
the user, which indicates whether the correct and ef-
fective distance between the surface to by treated on
the patient and the instrument probe has been main-
tained.
ON
OFF
ON
Start/Stop switch
Commissioning
3.2
Commissioning and explanation of the
converter
The
converter
plug con-
nector has a push-pull
lock. Plug the converter
plug connector into the
If the distance is cor-
yellow socket at the rear
rect, this LED display il-
of the energy control
luminates at intervals.
unit. The white point of
If the distance is not
the plug connector must
correct, the LED display
face upwards.
remains dark.
After 7 seconds, the
3.3
Commissioning and explanation of the
treatment unit switches
instrument probes
off for safety reasons.
The steps of the LED dis-
play
TIME/MIN
give a
visual and acoustic indi-
cation of the treatment
time which has elapsed.
For recommended treat-
ment times, please refer
to the indications table.
After 2.5 minutes, the
treatment unit switches
off completely for safety
instrument probe
Plug the
reasons.
for the corresponding indication) with the metal sec-
tion into the converter. Pull the silicon ring towards
The converter is started
the converter to secure the connection of the instru-
with the
START/STOPP
Then press START on the converter or on
ment probe.
button at the lower right
the energy control unit.
of the energy control
unit.
There is also a start/
Please note that the instrument probe
stop switch directly on
must be firmly inserted into the con-
the converter.
verter before pressing the START/STOP
button on the converter or on the en-
ergy control unit!
The instrument probe type depends on the area to be
treated. The wide range of plasma MEDICAL SYS-
TEMS® instrument probes provides access to almost
any treatment point on or in the human body.
Socket for converter
(depending on the type
plasma ONE · Instruction Manual
6-7