Mechanical installation
20
flange, the values given in the specifications can be
exceeded. In this case, ensure static temperature ratios
by cooling or heating, depending on the application. As
an alternative, check if thermal decoupling is possible,
e.g. by means of heat radiating elements such as multi­
ple disc couplings.
5.3

Installation orientation

The torque flange can be installed with any orientation.
With clockwise torque, the output frequency is 60 to
90 kHz for Option 5, Code DU2 (Option 5, Code SU2: 10
to 15 kHz; Option HU2: 240 to 360 kHz). In conjunction
with HBM amplifiers or when using the voltage output, a
positive output signal (0 V to +10 V) is present. In the
case of the rotational speed measuring system, an arrow
is attached to the stator housing to clearly define the
direction of rotation: if the measurement flange turns in
the direction of the arrow, connected HBM measuring
amplifiers deliver a positive output signal.
5.4

Installation options

There are basically two options for mounting the torque
flange: with or without dismantling the antenna ring. We
recommend mounting as described in Chapter 5.4.1. If
mounting in accordance with Chapter 5.4.1 is not possi­
ble, (e.g. in the case of subsequent stator replacement),
you will have to dismantle the antenna ring. It is essential
in this case to comply with the notes on assembling the
antenna segments (see Chapter 5.4.2).
A3452-13.0 HBM: public
T40B

Quicklinks ausblenden:

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis