Press the Plus /Minusbutton (H/G) repeatedly
until the desired value is reached or press and hold
the button (the values now run smoothly in the re-
spective direction) and release when the desired
value is reached.
3.
Set the speed (D): Use this button to set the speed
at which the construction dryer operates.
Running time of the product (Fig. 5)
The total running time of the product is shown on the
LCD display (1) via the operating hours counter (E).
9.3
Starting operation (Fig. 1 - 7)
1.
Only operate the product with the water tank (7)
inserted and optionally also with the drain hose (6)
supplied.
2.
Attention: Please check that the sealing plug (7a)
(for using the water tank (7)) is screwed on tightly.
Otherwise, it can lead to unwanted water leaks un-
der your product.
3.
Place the product on a horizontal, level surface
before using it.
4.
Insert the plug of the mains cable into the socket.
The product confirms this with a signal tone. The
LCD display (5) now shows the ambient humidity (J).
5.
Now the dehumidification value can be set be-
tween min. 30% and max. 80% using the Plus/
Minus buttons (H/G) (the symbol for dehumidifi-
cation mode (A) flashes during this process)
6.
Once you have set the desired value, wait 5 sec-
onds until the value is saved by the building dry-
er. The symbol for dehumidification mode (A) now
stops flashing and the construction dryer starts.
The ambient humidity display (J) shows the change.
9.4
Automatic defrosting (Fig. 1, 5)
At low ambient temperature, the product starts auto-
matic defrosting. In this phase, the cooling fan operates
normally, only the built-in compressor switches off. The
symbol for automatic defrosting (C) and the symbol for
setting the speed (F) light up on the LCD display (5)
during this phase.
The lower the ambient temperature at which the prod-
uct is operated, the earlier or more often the automatic
defrosting is activated. Once the defrosting process is
complete, the product continues to operate in the pre-
viously selected setting.
During automatic defrosting (C), the compressor is
switched off and the fan continues to run normally.
9.5
Emptying the water tank (7) (Fig. 1, 5, 6)
When the water tank (7) is completely filled with water,
this is indicated by the level indicator symbol (B) on the
LCD display (5) and "FU" also appears on the LCD dis-
play (5). In addition, an audible signal sounds after 5 sec-
onds and the product stops the dehumidification process.
1.
Switch the product off.
2.
Open the housing door (3).
3.
Remove the water tank (7) and empty it.
4.
Reinsert the water tank (7). Ensure that you place
the water tank (7) in the correct position.
5.
Close the housing door (3).
6.
Switch the product on again. The icon and fault
error E4 are no longer displayed. If the icon and
the fault error are still shown on the LCD display
(5), remove the water tank (7) again and reinsert it.
Note:
The water tank (7) must be fully inserted into the prod-
uct, otherwise the condensation water cannot be col-
lected properly.
9.6
Important working instructions
• To protect the compressor, it does not switch on again
immediately after the product has stopped operating
or there has been an interruption in operation (e.g.
emptying the water tank (7)). The compressor is in-
itially in a so-called "protection mode" for approx. 3
.
minutes before the compressor switches on again.
• The temperature range in which the product can
work properly is from approx. +5°C to approx. +35°C.
• We recommend maintaining a safety distance be-
tween the wall and the air inlet (4).
• Please empty the water tank (7) after each use of
the product.
• If you do not wish to use the product for an extended
period, disconnect the product from the power sup-
ply and attach the power cable to the product.
• Please do not tilt the construction dryer more than
45°, neither during transport nor during use.
• If the construction dryer has been accidentally tilted, wait
at least 12 hours before using the construction dryer.
10. Maintenance & Cleaning
The product is designed for problem-free operation
and minimal monitoring.
All moving parts are permanently lubricated.
The producthas no further internal parts that require
maintenance.