9.
Layout
Warning!
Always remove the mains plug before carrying out ad-
justments on the product.
Fitting of a suction line (Fig. 1)
1.
Screw a suction hose (plastic hose at least 19 mm
(3/4") directly or with a threaded nipple to the suc-
tion connection (5) approx. 30.75 mm (G1") of the
pump.
2.
Lay the suction line rising from the water pick-up
point to the pump. Ensure that the suction line is
not laid above the pump height. Air bubbles in the
suction line delay and prevent the suction process.
3.
Attach the suction and pressure lines so that
they do not exert any mechanical pressure on the
pump.
4.
The suction line should be located deep enough in
the water to prevent the pump from running dry if
the water level drops.
5.
A leaking suction line will prevent the water from
being sucked in due to air ingress.
6.
Avoid sucking in foreign bodies (sand etc.).
Filling the pump with water (Fig. 3)
m NOTE!
To reduce the start-up time of the pump and to prevent
air from being sucked in, the pump must be filled with
water beforehand!
1.
The suction line should already be fitted for this
purpose to prevent water from flowing out of the
suction connection (5).
2.
Fill the pump with water via the opening of the
pressure connection (1). Alternatively, water can
be poured in through the opening of the pre-filter
plug (6).
3.
Tilt the pump slightly in between to avoid air pockets.
4.
Now attach the pressure line as described in the
next point.
Fitting of a pressure line (Fig. 1)
1.
Connect the pressure line (at least 19 mm (3/4"))
directly or via a threaded nipple to the pressure
connection (1) approx. 30.75 mm (G1") of the
pump.
2.
During the suction process, open the shut-off de-
vices (spray nozzles, valves, etc.) in the pressure
line completely so that the air present in the suc-
tion line can escape freely.
10. Start-up
m Attention!
Always make sure the product is fully assembled
before commissioning!
1.
Place the product on a firm, level and horizontal
location.
2.
Open the pressure line.
3.
Connect the mains lead.
4.
Switch the product on using the on/off switch (3).
Suction can take up to 5 minutes at max. suction
head.
5.
Switch the product off at the on/off switch (3) when
you have finished working.
m NOTE!
The pump must be absolutely leak-proof at the inlet
and outlet. Therefore, use Teflon sealing tape or seal-
ing hemp regardless of your chosen connection!
11. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the appli-
cable VDE and DIN provisions. The customer's mains
connection as well as the extension cable used must
also comply with these regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
www.scheppach.com