9. Troubleshooting
Problem
Rotary valve switches
off thermally
Rotary valve is not
turning
Rotary valve makes
"screaming" noise
Material will not pass
the valve without
accumulation
Rotation disk doesn't
turn but rotor does
Rotation detector
doesn't react
Paint is
chipping/peeling
18
User manual | RVA Rotary valves ATEX
www.formula-air. com
Probable cause
Foreign body got stuck
Rotor frozen
Gear motor defective
Rotor defective
Motor protection set incorrectly
Fuse defective
Big voltage drop in power supply
Working switch is off
Motor protection switched of thermally
Conditions of operation are not met in the
control system
Fuse defective
It might be that something is stuck in the
rotary valve
It might be that the motor or gearbox is
broken
It might be that the motor or gearbox
shaft key is broken
Foreign body got stuck
Rotor/rotary valve body is defective
The rotor turns the wrong way
Rotor shaft is warped
Rotor bearings are shot
Lack of material going through, Empty
rubber vanes turning on metal
Volume of material per rotation is larger
than planned
Very high pressure difference (too high
under-pressure)
Settling velocity of material less than
expected
Rubber blade vanes are damaged, air
passes
The material accumulates in lumps which
cannot pass
The material is not removed fast enough
at the outlet of the rotary valve
Transported material is too big/bulky
Material agglutinates
Material is wet or sticky
Rotation disk and rotor axle are no longer
consolidated
Rotary valve isn't running
Cable is not connected
Improperly connected cables
Rotation disk isn't turning
Detection distance is too big or too short
High temperature material going through
External environment factors
Rubber blade vane friction on carcass
Possible solution
Remove foreign body
Thaw on the outside with hot air or water
Replace motor, or gearbox
Replace rotor
Adjust the motor protection
Replace fuse
Insure voltage consistency
Stop the installation, switch on the
working switch
See "Rotary valve switches off thermally"
Investigate why conditions are not met
Replace fuse
Investigate that nothing is stuck in the
rotor
Investigate if a part is broken and needs
to be replaced
Remove foreign body
Replace defective component
Wire the motor correctly
Change complete rotor
Replace rotor bearings
Resize rotary valve
See "Material will not pass the valve
without accumulation"
Reduce the volume of material feed, or
replace rotary valve
More frequent regeneration
Replace rotary valve (with seals)
Shorter step-interval of chain conveyor
Replace rubber blade vanes
Adjust the production machine to change
the flow of material
Check the proper functioning of the
emptying system
Use the adequate rotary valve
Wrong application for the rotary valves
Tighten rotation disk on rotor axle
Turn on rotary valve
Make sure cables are connected
Insure proper cable connection
See" Rotation disk doesn't turn but rotor
does"
Verify installation distance
Reduce material temperature
Inappropriate use
Place indoors
Inappropriate use
See "Rotary valve makes "screaming"
noise"