7.2 Spare parts :

Code
JCAB000028
Bearing for RVA-X ATEX rotary valve (all models)
JCAB000032
Set of rubber blade vanes (6 pcs) for RVA1-X
JCAB000033
Set of rubber blade vanes (6 pcs) for RVA2-X
JCAB000034
Set of rubber blade vanes (6 pcs) for RVA3-X
JCAB000035
Set of rubber blade vanes (6 pcs) for RVA4-X
JCAB000027
Felt seals kit for all RVA-X ATEX rotary valve models - 2 seal rings per rotor
JEBD000001
Gearbox ATEX2GD for motor 0,37kW
JEBD000002
Gearbox ATEX2GD for motor 0,55kW
JEAB000003
Motor 2D suitable for ATEX zone 21- IE2 - 0,37kW - 4Pole - 230/400V - 50Hz
JEAB000001
Motor 3GD suitable for ATEX zone 22 - IE2 - 0,37kW - 4Pole - 230/400V - 50Hz
JEAA000005
Motor non-ATEX - IE2 - 0,37kW - 4Pole - 230/400V - 50Hz
JEAB000004
Motor 2D suitable for ATEX zone 21 IE2 - 0,55kW - 4Pole - 230/400V - 50Hz
JEAB000002
Motor 3GD suitable for ATEX zone 22 - IE2 - 0,55kW - 4Pole - 230/400V - 50Hz
JEAA000006
Motor non-ATEX - IE2 - 0,55kW - 4Pole - 230/400V - 50Hz
JCAB000036
Complete rotor RVA1 -Xi-06
JCAB000037
Complete rotor RVA2 -Xi-06
JCAB000038
Complete rotor RVA3 -Xi-06
JCAB000039
Complete rotor RVA4 -Xi-06
8.

Rotation detector (optional)

The optional inductive rotation detector is an optical detection system that controls if the rotation disk is turning. In
case of rotation failure, it sends a signal to a control panel.
8.1

Placing the rotation detector

CAUTION !
Before any manipulation to the RVA-X ATEX rotary valve, make sure that that system is switched off, and that it is
impossible to inadvertently set it back in operation.
NOTE
: all electrical manipulations should be performed by qualified personnel only.
Step 1 : Remove the rotation disk protection cover by untightening the bolts holding it on the RVA-X ATEX rotary valve
body,
Step 2 : Introduce the sensor in the hole on the top of the front of the over and tighten it in place with the nuts supplied
with the detector,
16