EMA Components Topas Pro/Rubin Pro/Rubin Pro D-III series safes data sheet
2-door safe
(Picture shows Rubin Pro 70, the protection plate is hidden for this illustration)
1)
Structure-borne sound detector in both doors and body
2)
Distributor in right-hand door and body
3+4)
Door contact in both doors and body
5)
Main lock
6)
Cable transition with end pieces (inner diameter 7mm) Link
7)
Breakaway detector (standard at the rear next to the structure-borne sound detector)
8)
External lock bolt contact (Link type 1001330A or Schitronik type 035501)
9)
Cable outlet hole rear panel (diameter 11mm)
10)
Floor mounting hole (standard 1 piece centrally)
11)
optional second lock on the sub-position
Safety seal
Illustration shows safe with two locks. As standard, the safe
is only equipped with a lock on pos. 5.
11.07.2024 / A1014188
Operating and mounting instructions
Rubin Pro - Safe
Safety seal
Important note!
As standard, the safe is equipped with a main lock on pos. 5.
The safe can optionally also be equipped with a second lock
on sub-position no. 11. The second lock does not need to be
monitored with a bolt contact switch.
Monitoring of lock bolt position:
Deadbolt lock:
Switch plate 1 or 2
(screwed to the lock
bolt)
Switch
16
DE/EN/FR/NL
Swingbolt lock:
Switch plate 3 (screwed to
the lower base of the bolt
mechanism)
Bolt contact switch