EMA Components Topas Pro/Rubin Pro/Rubin Pro D-III series safes data sheet
1-door safe
(Picture shows Rubin Pro from size 10, the protection plate is hidden for this illustration)
1)
Structure-borne sound detector in door and body
2)
Distributor in door and body
3+4)
Door contact
5)
Main lock
6)
Cable transition with end pieces (inner diameter 7mm) Link
7)
Breakaway detector (standard at the rear next to the structure-borne sound detector)
8)
External lock bolt contact (Link type 1001330A or Schitronik type 035501)
9) Cable outlet hole rear wall (diameter 11mm)
10)
Floor mounting hole (standard 1 piece centrally)
11)
optional second lock on the sub-position
Illustration shows safe with two locks. As standard, the safe
is only equipped with a lock on pos. 5.
11.07.2024 / A1014188
Operating and mounting instructions
Rubin Pro - Safe
Safety seal
Switch
Important note!
As standard, the safe is equipped with a main lock on pos. 5.
The safe can optionally also be equipped with a second lock
on sub-position no. 11. The second lock does not need to be
monitored with a bolt contact switch.
Monitoring of lock bolt position:
Deadbolt lock:
Switch plate 1 or 2
(screwed to the lock
bolt)
Bolt contact switch
(pressed)
15
DE/EN/FR/NL
Swingbolt lock:
Switch plate 3 (screwed to
the lower base of the bolt
mechanism)